Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0276 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,544 | $48,000 | Implemented |
BD0276 # 03 Y:2005 | 03 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $8,381 | $2,000 | Not Implemented |
BD0276 # 04 Y:2005 | 04 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,365 | $13,346 | n/a |
BD0276 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,120 | $740 | Not Implemented |
BD0276 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,665 | $225 | Not Implemented |
BD0276 # 07 Y:2005 | 07 | 2005 | INSTALL TURBULATORS | $1,362 | $2,150 | Not Implemented |
BD0276 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $474 | $800 | Not Implemented |
BD0276 # 09 Y:2005 | 09 | 2005 | RECOVER AND REUSE COOLING WATER | $1,360 | $4,000 | Not Implemented |
LM0087 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,069 | $17,418 | Implemented |
LM0087 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,466 | $760 | Implemented |
LM0087 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,413 | $0 | Not Implemented |
LM0087 # 04 Y:2005 | 04 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,685 | $450 | Not Implemented |
LM0087 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $244 | $377 | Implemented |
LM0087 # 06 Y:2005 | 06 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,321 | $1,000 | Implemented |
LM0087 # 07 Y:2005 | 07 | 2005 | MODIFY WORKLOAD | $23,000 | $9,700 | Not Implemented |
LM0087 # 08 Y:2005 | 08 | 2005 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $19,500 | $3,680 | Implemented |
IC0092 # 01 Y:2004 | 01 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $4,234 | $30 | Not Implemented |
IC0092 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,325 | $0 | Not Implemented |
IC0092 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $28,152 | $6,700 | Not Implemented |
IC0092 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $900 | $2,340 | Not Implemented |
IC0092 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,634 | $0 | Not Implemented |
IC0092 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,783 | $17,315 | Not Implemented |
IC0092 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $1,544 | Not Implemented |
IC0092 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $1,120 | $3,002 | Not Implemented |
IC0092 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,934 | $38,438 | Not Implemented |