Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0806 # 13 Y:2009 | 13 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,419 | $748 | Not Implemented |
UD0806 # 01 Y:2009 | 01 | 2009 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $169,364 | $0 | Implemented |
UD0806 # 03 Y:2009 | 03 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,287 | $157,500 | Not Implemented |
UD0806 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,959 | $10,000 | Not Implemented |
UD0806 # 05 Y:2009 | 05 | 2009 | COVER OPEN TANKS | $11,513 | $5,220 | Not Implemented |
UD0806 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $75,878 | $0 | Implemented |
UD0806 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,111 | $12,665 | Implemented |
UD0806 # 11 Y:2009 | 11 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,165 | $11,747 | Not Implemented |
UD0806 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,652 | $990 | Implemented |
UD0806 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,025 | $3,000 | Not Implemented |
UD0806 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $10,900 | $5,010 | Not Implemented |
UD0806 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,909 | $17,420 | Implemented |
UD0806 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $8,238 | $64,000 | Not Implemented |
UD0806 # 18 Y:2009 | 18 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $624 | $1,000 | Implemented |
UD0806 # 15 Y:2009 | 15 | 2009 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,991 | $15,000 | Not Implemented |
UD0806 # 16 Y:2009 | 16 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,636 | $4,000 | Not Implemented |
UD0806 # 14 Y:2009 | 14 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,400 | $6,174 | Implemented |
UD0806 # 17 Y:2009 | 17 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,995 | $0 | Implemented |
OK0775 # 09 Y:2009 | 09 | 2009 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $19,665 | $140,000 | Not Implemented |
OK0775 # 08 Y:2009 | 08 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $30,940 | $0 | Not Implemented |
OK0775 # 07 Y:2009 | 07 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $5,419 | $386 | Not Implemented |
OK0775 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,586 | $4,119 | Not Implemented |
OK0775 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,179 | $9,264 | Not Implemented |
OK0775 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,208 | $11,677 | Implemented |
OK0775 # 03 Y:2009 | 03 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,617 | $5,534 | Not Implemented |