Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1811 # 05 Y:2018 | 05 | 2018 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,503 | $0 | Implemented |
UK1811 # 04 Y:2018 | 04 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $372 | $0 | Not Implemented |
UK1811 # 03 Y:2018 | 03 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,133 | $2,270 | Implemented |
UK1811 # 02 Y:2018 | 02 | 2018 | ELIMINATE/REDUCE AN OPERATION | $2,899 | $0 | Not Implemented |
UK1811 # 01 Y:2018 | 01 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,721 | $2,250 | Not Implemented |
UK1811 # 08 Y:2018 | 08 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $282 | $164 | Implemented |
UK1811 # 06 Y:2018 | 06 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $5,397 | $3,780 | Not Implemented |
UK1811 # 07 Y:2018 | 07 | 2018 | INSTALL OCCUPANCY SENSORS | $2,332 | $4,270 | Implemented |
LE0456 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,319 | $2,000 | Not Implemented |
LE0456 # 06 Y:2018 | 06 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,041 | $40,000 | Implemented |
LE0456 # 03 Y:2018 | 03 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,140 | $3,500 | Implemented |
LE0456 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $783 | $3,200 | Implemented |
LE0456 # 01 Y:2018 | 01 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,810 | $36 | Implemented |
LE0456 # 04 Y:2018 | 04 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,979 | $50,000 | Implemented |
AM0751 # 03 Y:2018 | 03 | 2018 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $27,160 | $10,000 | Not Implemented |
AM0751 # 08 Y:2018 | 08 | 2018 | INSTALL OCCUPANCY SENSORS | $650 | $470 | Implemented |
AM0751 # 07 Y:2018 | 07 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,310 | $7 | Implemented |
AM0751 # 06 Y:2018 | 06 | 2018 | OPTIMIZE PLANT POWER FACTOR | $2,005 | $3,520 | Implemented |
AM0751 # 05 Y:2018 | 05 | 2018 | INSULATE BARE EQUIPMENT | $4,980 | $500 | Implemented |
AM0751 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,355 | $1,000 | Implemented |
AM0751 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $12,430 | $20,750 | Implemented |
AM0751 # 01 Y:2018 | 01 | 2018 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $15,720 | $6,000 | Not Implemented |
WV0556 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,065 | $9,139 | Implemented |
WV0556 # 06 Y:2018 | 06 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,985 | $222 | Implemented |
WV0556 # 12 Y:2018 | 12 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $763 | $440 | Implemented |