Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
NAICS 332117 Powder Metallurgy Part Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0053 # 03 Y:2014 03 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $17,388 $9,552 Not Implemented
WM0053 # 13 Y:2014 13 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $560 $512 Implemented
WM0053 # 12 Y:2014 12 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,677 $19,918 Implemented
WM0053 # 11 Y:2014 11 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,232 $4,500 Not Implemented
WM0053 # 10 Y:2014 10 2014 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,892 $0 Implemented
WM0053 # 09 Y:2014 09 2014 IMPROVE SPACE COMFORT CONDITIONING $28,274 $1,139 Not Implemented
WM0053 # 08 Y:2014 08 2014 USE SYNTHETIC LUBRICANT $11,107 $3,750 Not Implemented
WM0053 # 07 Y:2014 07 2014 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $29,006 $100,000 Not Implemented
WM0053 # 06 Y:2014 06 2014 OPTIMIZE PLANT POWER FACTOR $35,215 $60,300 Not Implemented
WM0053 # 05 Y:2014 05 2014 USE OPTIMUM THICKNESS INSULATION $147,137 $3,600 Not Implemented
WM0053 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $12,709 $1,150 Not Implemented
WM0053 # 02 Y:2014 02 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $17,731 $1,292 Implemented
WM0053 # 01 Y:2014 01 2014 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $33,649 $31,395 Not Implemented
WI0452 # 01 Y:2003 01 2003 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $54,337 $72,000 n/a
WI0452 # 08 Y:2003 08 2003 USE OPTIMUM THICKNESS INSULATION $1,592 $687 Not Implemented
WI0452 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,926 $8,580 Not Implemented
WI0452 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $4,063 $1,000 Not Implemented
WI0452 # 05 Y:2003 05 2003 REPLACE CLOTH RAGS WITH PAPER TOWELS $4,710 $0 Not Implemented
WI0452 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $4,850 $2,700 Not Implemented
WI0452 # 03 Y:2003 03 2003 UPGRADE CONTROLS ON COMPRESSORS $5,692 $12,000 Not Implemented
WI0452 # 02 Y:2003 02 2003 BURN WASTE OIL FOR HEAT $44,636 $30,000 Not Implemented