IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

457

matching recommendations
Reset
NAICS 332119 Metal Crown, Closure, and Other Metal Stamping (except Automotive)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0464 # 08 Y:2013 08 2013 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,686 $400 Not Implemented
SD0464 # 09 Y:2013 09 2013 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,556 $500 Not Implemented
UK1212 # 01 Y:2012 01 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $15,105 $14,500 Not Implemented
UK1212 # 02 Y:2012 02 2012 UPGRADE CONTROLS ON COMPRESSORS $14,492 $15,000 Not Implemented
UK1212 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,414 $26,320 Implemented
UK1212 # 04 Y:2012 04 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,314 $2,240 Implemented
UK1212 # 05 Y:2012 05 2012 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $4,209 $3,430 Implemented
UK1212 # 06 Y:2012 06 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,607 $400 Not Implemented
UK1212 # 07 Y:2012 07 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,205 $4,270 Not Implemented
UK1212 # 08 Y:2012 08 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $609 $990 Not Implemented
UK1212 # 09 Y:2012 09 2012 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $17,314 $0 Not Implemented
UK1212 # 10 Y:2012 10 2012 OPTIMIZE PLANT POWER FACTOR $4,850 $7,500 Not Implemented
UK1212 # 11 Y:2012 11 2012 PAY UTILITY BILLS ON TIME $1,535 $0 Implemented
MZ0096 # 01 Y:2012 01 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $57,095 $67,348 Implemented
MZ0096 # 02 Y:2012 02 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $28,732 $29,201 Implemented
MZ0096 # 03 Y:2012 03 2012 COMBINE UTILITY METERS $19,635 $10,000 Not Implemented
MZ0096 # 04 Y:2012 04 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $15,197 $16,000 Not Implemented
MZ0096 # 05 Y:2012 05 2012 USE RADIANT HEATER FOR SPOT HEATING $11,800 $22,100 Implemented
MZ0096 # 06 Y:2012 06 2012 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $6,087 $3,554 Not Implemented
MZ0096 # 07 Y:2012 07 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $5,395 $5,400 Implemented
MZ0096 # 08 Y:2012 08 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $896 $221 Implemented
MZ0096 # 09 Y:2012 09 2012 USE PHOTOCELL CONTROLS $507 $560 Implemented
MZ0096 # 10 Y:2012 10 2012 INSTALL OCCUPANCY SENSORS $455 $480 Implemented
MZ0096 # 11 Y:2012 11 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $467 $480 Implemented
UD0858 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,297 $12,425 Not Implemented