Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
96
matching recommendationsNAICS | 332215 | Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0441 # 03 Y:2012 | 03 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $73,647 | $33,378 | Implemented |
WV0441 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $64,675 | $91,200 | Implemented |
WV0441 # 05 Y:2012 | 05 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $49,557 | $11,000 | Implemented |
WV0441 # 06 Y:2012 | 06 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $38,793 | $10,750 | Implemented |
WV0441 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $20,023 | $6,777 | Not Implemented |
WV0441 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,024 | $37,887 | Implemented |
WV0441 # 09 Y:2012 | 09 | 2012 | OPTIMIZE PLANT POWER FACTOR | $10,618 | $46,340 | Not Implemented |
WV0441 # 11 Y:2012 | 11 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,115 | $3,000 | Not Implemented |
WV0441 # 12 Y:2012 | 12 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,825 | $12,850 | Not Implemented |
WV0441 # 13 Y:2012 | 13 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,782 | $0 | Implemented |
WV0441 # 14 Y:2012 | 14 | 2012 | IMPROVE LUBRICATION PRACTICES | $2,709 | $3,400 | Not Implemented |
WV0441 # 15 Y:2012 | 15 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,137 | $1,063 | Implemented |
MA0677 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $9,048 | $2,585 | Implemented |
MA0677 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $4,053 | $200 | Not Implemented |
MA0677 # 03 Y:2011 | 03 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $1,514 | $5,967 | Implemented |
MA0677 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,225 | $200 | Implemented |
MA0677 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $912 | $8,300 | Not Implemented |
MA0677 # 06 Y:2011 | 06 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $362 | $500 | Implemented |
MA0677 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $107 | $100 | Implemented |
LL0280 # 02 Y:2007 | 02 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,024 | $210 | Implemented |
LL0280 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,405 | $1,880 | Implemented |
LL0280 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $111 | $92 | Not Implemented |
LL0280 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $1,816 | $558 | Not Implemented |
LL0280 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $1,780 | $1,662 | Not Implemented |