Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,176

matching recommendations
Reset
NAICS 3323 Architectural and Structural Metals Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0472 # 11 Y:2016 11 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $173 Not Implemented
LE0407 # 01 Y:2016 01 2016 INSTALL OCCUPANCY SENSORS $143 $0 Not Implemented
LE0407 # 02 Y:2016 02 2016 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $19,792 $25 Implemented
LE0407 # 03 Y:2016 03 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,305 $1,800 Not Implemented
LE0407 # 04 Y:2016 04 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $707 $200 Not Implemented
LE0407 # 05 Y:2016 05 2016 INSTALL OCCUPANCY SENSORS $7,907 $12,234 Not Implemented
LE0407 # 06 Y:2016 06 2016 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,031 $9,467 Not Implemented
LE0407 # 07 Y:2016 07 2016 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,016 $28,500 Not Implemented
BD0471 # 01 Y:2015 01 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $18,915 $20 Not Implemented
BD0471 # 02 Y:2015 02 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,951 $7,711 Not Implemented
BD0471 # 03 Y:2015 03 2015 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $2,184 $6,000 Not Implemented
BD0471 # 04 Y:2015 04 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,732 $500 Implemented
BD0471 # 05 Y:2015 05 2015 INSTALL OCCUPANCY SENSORS $888 $450 Not Implemented
BD0471 # 06 Y:2015 06 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $417 $300 Not Implemented
BD0471 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $245 $225 Not Implemented
BD0471 # 08 Y:2015 08 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $356 $20 Not Implemented
BD0471 # 09 Y:2015 09 2015 REVISE RAW MATERIAL SPECS $90,750 $7,000 Not Implemented
BD0471 # 10 Y:2015 10 2015 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $86,400 $1,050 Implemented
BD0469 # 01 Y:2015 01 2015 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $2,898 $4,090 Not Implemented
BD0469 # 02 Y:2015 02 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,562 $4,770 Not Implemented
BD0469 # 03 Y:2015 03 2015 INSTALL OCCUPANCY SENSORS $2,198 $750 Not Implemented
BD0469 # 04 Y:2015 04 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $761 $455 Implemented
BD0469 # 05 Y:2015 05 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $681 $20 Not Implemented
BD0469 # 06 Y:2015 06 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $623 $700 Not Implemented
BD0469 # 07 Y:2015 07 2015 RECOVER WASTE HEAT FROM EQUIPMENT $591 $1,000 Not Implemented