Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,058
matching recommendationsNAICS | 33231 | Plate Work and Fabricated Structural Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0812 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,893 | $6,240 | Not Implemented |
UD0812 # 03 Y:2010 | 03 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,148 | $0 | Not Implemented |
UD0812 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,589 | $1,000 | Not Implemented |
UD0812 # 05 Y:2010 | 05 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,047 | $12,500 | Not Implemented |
UD0812 # 06 Y:2010 | 06 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,040 | $16,000 | Not Implemented |
UD0812 # 07 Y:2010 | 07 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,750 | $21,000 | Not Implemented |
UD0812 # 08 Y:2010 | 08 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,335 | $2,310 | Not Implemented |
UD0812 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $4,280 | $3,600 | Not Implemented |
UD0812 # 10 Y:2010 | 10 | 2010 | OPTIMIZE PLANT POWER FACTOR | $1,963 | $5,000 | Not Implemented |
UD0812 # 11 Y:2010 | 11 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $800 | $2,500 | Not Implemented |
UD0812 # 12 Y:2010 | 12 | 2010 | INSTALL AUTOMATIC STACK DAMPER | $20,826 | $200 | Not Implemented |
UD0812 # 13 Y:2010 | 13 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,114 | $70,000 | Not Implemented |
UD0812 # 14 Y:2010 | 14 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,930 | $10,000 | Not Implemented |
UD0812 # 15 Y:2010 | 15 | 2010 | INSTALL AUTOMATIC STACK DAMPER | $15,975 | $8,500 | Not Implemented |
BD0369 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,238 | $55,259 | Not Implemented |
BD0369 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $28,395 | $14,100 | Not Implemented |
BD0369 # 03 Y:2010 | 03 | 2010 | DISCONNECT BALLASTS | $4,206 | $205 | Not Implemented |
BD0369 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $567 | $400 | Not Implemented |
BD0369 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $371 | $1,000 | Not Implemented |
BD0369 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $590 | $730 | Not Implemented |
BD0369 # 07 Y:2010 | 07 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $8,016 | $6,890 | Not Implemented |
BD0369 # 08 Y:2010 | 08 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,703 | $2,500 | Not Implemented |
BD0369 # 09 Y:2010 | 09 | 2010 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $386 | $1,898 | Not Implemented |
BD0369 # 10 Y:2010 | 10 | 2010 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $20,730 | $17,200 | Not Implemented |
SF0379 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,329 | $0 | Implemented |