Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
76
matching recommendationsNAICS | 33231 | Plate Work and Fabricated Structural Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0366 # 08 Y:2012 | 08 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $263 | $368 | Not Implemented |
LL0366 # 09 Y:2012 | 09 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $161 | $115 | Not Implemented |
LL0243 # 08 Y:2006 | 08 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $135 | $198 | Not Implemented |
LL0243 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $509 | $350 | Implemented |
LL0243 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $527 | $30 | Implemented |
LL0243 # 05 Y:2006 | 05 | 2006 | USE PHOTOCELL CONTROLS | $538 | $270 | Implemented |
LL0243 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $932 | $372 | Implemented |
LL0243 # 02 Y:2006 | 02 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $8,399 | $1,521 | Not Implemented |
LL0243 # 01 Y:2006 | 01 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,455 | $575 | Not Implemented |
LL0243 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,122 | $440 | Implemented |
LL0195 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $350 | Implemented |
LL0195 # 09 Y:2004 | 09 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $412 | $226 | Implemented |
LL0195 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $60 | Implemented |
LL0195 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $225 | $240 | Implemented |
LL0195 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,111 | $3,200 | Implemented |
LL0195 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $4,294 | $1,320 | Implemented |
LL0195 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,732 | $4,280 | Implemented |
LL0195 # 02 Y:2004 | 02 | 2004 | USE PHOTOCELL CONTROLS | $11,834 | $750 | Implemented |
LL0195 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $29,145 | $4,275 | Not Implemented |
LL0175 # 07 Y:2003 | 07 | 2003 | COMBINE UTILITY METERS | $1,625 | $0 | Not Implemented |
LL0175 # 06 Y:2003 | 06 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $40,875 | $100,279 | Not Implemented |
LL0175 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $594 | $800 | Not Implemented |
LL0175 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $746 | $56 | Not Implemented |
LL0175 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,190 | $15 | Not Implemented |
LL0175 # 02 Y:2003 | 02 | 2003 | USE PHOTOCELL CONTROLS | $3,273 | $280 | Not Implemented |