Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,123
matching recommendationsNAICS | 33232 | Ornamental and Architectural Metal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0556 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,881 | $4,905 | Implemented |
IA0556 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $1,796 | $3,898 | Implemented |
IA0556 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,632 | $513 | Implemented |
IA0556 # 06 Y:2016 | 06 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,391 | $462 | Not Implemented |
IA0556 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,271 | $90 | Implemented |
IA0556 # 08 Y:2016 | 08 | 2016 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $880 | $120 | Implemented |
UD0945 # 01 Y:2016 | 01 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $5,063 | $8,000 | Implemented |
UD0945 # 02 Y:2016 | 02 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $527 | $0 | Implemented |
UD0945 # 03 Y:2016 | 03 | 2016 | REDUCE FLUID FLOW RATES | $7,163 | $0 | Implemented |
UD0945 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $623 | $30 | Implemented |
UD0945 # 05 Y:2016 | 05 | 2016 | REDUCE VENTILATION AIR | $77,225 | $18,850 | Not Implemented |
UD0945 # 06 Y:2016 | 06 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,486 | $8,972 | Not Implemented |
UD0945 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,610 | $0 | Not Implemented |
UD0945 # 08 Y:2016 | 08 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,209 | $3,951 | Not Implemented |
UD0945 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,501 | $0 | Not Implemented |
UD0945 # 10 Y:2016 | 10 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,904 | $23,828 | Not Implemented |
UD0945 # 11 Y:2016 | 11 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,976 | $0 | Implemented |
UD0945 # 12 Y:2016 | 12 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $3,983 | $20,370 | Implemented |
UD0945 # 13 Y:2016 | 13 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,867 | $300 | Not Implemented |
UD0945 # 14 Y:2016 | 14 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $756 | $300 | Not Implemented |
UA0154 # 01 Y:2016 | 01 | 2016 | MODIFY STARTUP/SHUTDOWN TIMES | $3,959 | $0 | Not Implemented |
UA0154 # 02 Y:2016 | 02 | 2016 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,116 | $1,660 | Not Implemented |
UA0154 # 03 Y:2016 | 03 | 2016 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $201 | $508 | Not Implemented |
UA0154 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $566 | $2,045 | Not Implemented |
UA0154 # 05 Y:2016 | 05 | 2016 | USE PHOTOCELL CONTROLS | $414 | $664 | Not Implemented |