IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

120

matching recommendations
Reset
NAICS 3324 Boiler, Tank, and Shipping Container Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0649 # 10 Y:2014 10 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $235 $30 Implemented
AM0649 # 09 Y:2014 09 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $250 $55 Implemented
AM0649 # 08 Y:2014 08 2014 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $650 $0 Implemented
AM0649 # 07 Y:2014 07 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $770 $60 Not Implemented
AM0649 # 03 Y:2014 03 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $13,490 $150 Not Implemented
AM0649 # 04 Y:2014 04 2014 INSULATE BARE EQUIPMENT $8,110 $200 Not Implemented
AM0649 # 05 Y:2014 05 2014 USE SYNTHETIC LUBRICANT $3,690 $0 Implemented
OK0860 # 09 Y:2013 09 2013 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,499 $3,850 Not Implemented
OK0860 # 01 Y:2013 01 2013 INSTALL SET-BACK TIMERS $3,227 $1,723 Not Implemented
OK0860 # 02 Y:2013 02 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,823 $5,100 Not Implemented
OK0860 # 03 Y:2013 03 2013 USE RADIANT HEATER FOR SPOT HEATING $3,126 $26,250 Not Implemented
OK0860 # 04 Y:2013 04 2013 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,366 $14,850 Not Implemented
OK0860 # 05 Y:2013 05 2013 INCREASE AMOUNT OF CONDENSATE RETURNED $3,223 $3,250 Not Implemented
OK0860 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,722 $1,750 Implemented
OK0860 # 07 Y:2013 07 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $986 $513 Not Implemented
OK0860 # 12 Y:2013 12 2013 INSTALL OCCUPANCY SENSORS $445 $3,675 Implemented
OK0860 # 11 Y:2013 11 2013 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $32,972 $69,860 Not Implemented
OK0860 # 10 Y:2013 10 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,580 $12,694 Not Implemented
OK0860 # 08 Y:2013 08 2013 RECOVER WASTE HEAT FROM EQUIPMENT $3,206 $847 Not Implemented
AM0603 # 06 Y:2012 06 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,080 $1,000 Implemented
AM0603 # 07 Y:2012 07 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,040 $500 Implemented
AM0603 # 08 Y:2012 08 2012 PAY UTILITY BILLS ON TIME $1,684 $0 Implemented
AM0603 # 09 Y:2012 09 2012 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,655 $0 Not Implemented
AM0603 # 10 Y:2012 10 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,180 $3,110 Implemented
AM0603 # 11 Y:2012 11 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $720 $20 Implemented