Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
125
matching recommendationsNAICS | 3324 | Boiler, Tank, and Shipping Container Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0499 # 06 Y:2005 | 06 | 2005 | OPTIMIZE PLANT POWER FACTOR | $2,270 | $5,600 | Not Implemented |
AM0499 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,380 | $1,080 | Not Implemented |
AM0499 # 08 Y:2005 | 08 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $735 | $0 | Implemented |
AM0499 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM THICKNESS INSULATION | $505 | $35 | Not Implemented |
AM0499 # 10 Y:2005 | 10 | 2005 | USE OPTIMUM THICKNESS INSULATION | $270 | $40 | Not Implemented |
AM0486 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,394 | $50 | Implemented |
AM0486 # 02 Y:2005 | 02 | 2005 | INSTALL SKYLIGHTS | $1,020 | $0 | Implemented |
AM0486 # 03 Y:2005 | 03 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $710 | $290 | Implemented |
AM0486 # 04 Y:2005 | 04 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $702 | $0 | Implemented |
AM0486 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $502 | $400 | Implemented |
AM0486 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $448 | $307 | Implemented |
AM0486 # 07 Y:2005 | 07 | 2005 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $175 | $700 | Implemented |
TA0089 # 01 Y:2004 | 01 | 2004 | MOVE BOILER TO MORE EFFICIENT LOCATION | $87,420 | $4,860 | Implemented |
TA0089 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,060 | $540 | Implemented |
TA0089 # 03 Y:2004 | 03 | 2004 | INSULATE BARE EQUIPMENT | $10,000 | $3,200 | Implemented |
TA0089 # 04 Y:2004 | 04 | 2004 | USE MINIMUM SAFE OVEN VENTILATION | $1,890 | $1,500 | Implemented |
TA0089 # 05 Y:2004 | 05 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,740 | $0 | Implemented |
AM0466 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,850 | $6,300 | Implemented |
AM0466 # 02 Y:2004 | 02 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,595 | $6,000 | Not Implemented |
AM0466 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,980 | $0 | Implemented |
AM0466 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,810 | $500 | Implemented |
AM0466 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,125 | $1,070 | Not Implemented |
AM0466 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $790 | $215 | Implemented |
AM0466 # 07 Y:2004 | 07 | 2004 | PAY UTILITY BILLS ON TIME | $600 | $0 | Implemented |
AM0466 # 08 Y:2004 | 08 | 2004 | USE SYNTHETIC LUBRICANT | $279 | $0 | Implemented |