Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

205

matching recommendations
Reset
NAICS 33242 Metal Tank (Heavy Gauge) Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0358 # 01 Y:2007 01 2007 IMPROVE COMBUSTION CONTROL CAPABILITY $91,739 $34,400 Not Implemented
WV0358 # 02 Y:2007 02 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $27,409 $34,100 Not Implemented
WV0358 # 03 Y:2007 03 2007 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $20,287 $6,050 Implemented
WV0358 # 04 Y:2007 04 2007 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $24,675 $15,300 Implemented
WV0358 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,775 $8,600 Implemented
WV0358 # 06 Y:2007 06 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,908 $5,830 Not Implemented
WV0358 # 07 Y:2007 07 2007 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,651 $1,000 Implemented
WV0358 # 08 Y:2007 08 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,029 $0 Implemented
WV0358 # 09 Y:2007 09 2007 DEVELOP A REPAIR/REPLACE POLICY $1,016 $555 Implemented
WV0358 # 10 Y:2007 10 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $998 $1,555 Implemented
WV0358 # 11 Y:2007 11 2007 INSTALL OCCUPANCY SENSORS $679 $2,103 Implemented
WV0358 # 12 Y:2007 12 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $468 $78 Implemented
WV0358 # 13 Y:2007 13 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $432 $119 Not Implemented
WV0358 # 14 Y:2007 14 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $410 $22 Not Implemented
LL0186 # 01 Y:2004 01 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $29,094 $4,650 Implemented
LL0186 # 02 Y:2004 02 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,122 $48 Not Implemented
LL0186 # 03 Y:2004 03 2004 USE PHOTOCELL CONTROLS $7,508 $600 Not Implemented
LL0186 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,551 $195 Implemented
LL0186 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,104 $2,080 Implemented
LL0186 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,748 $4,250 Implemented
LL0186 # 07 Y:2004 07 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,313 $96 Not Implemented
LL0186 # 08 Y:2004 08 2004 INSTALL OCCUPANCY SENSORS $694 $90 Not Implemented
LL0186 # 09 Y:2004 09 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $452 $315 Implemented
LL0186 # 10 Y:2004 10 2004 COMBINE UTILITY METERS $2,613 $720 Implemented
LL0186 # 11 Y:2004 11 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $60 Implemented