Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
182
matching recommendationsNAICS | 332510 | Hardware Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0948 # 05 Y:2016 | 05 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,007 | $926 | Not Implemented |
OK0948 # 06 Y:2016 | 06 | 2016 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $27,228 | $83,600 | Implemented |
OK0948 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,797 | $118,583 | Not Implemented |
OK0948 # 08 Y:2016 | 08 | 2016 | USE OPTIMUM THICKNESS INSULATION | $382 | $1,310 | Implemented |
OK0948 # 09 Y:2016 | 09 | 2016 | USE OPTIMUM THICKNESS INSULATION | $58 | $203 | Implemented |
OK0948 # 10 Y:2016 | 10 | 2016 | USE POWER DURING OFF-PEAK PERIODS | $12,184 | $0 | Not Implemented |
OK0948 # 11 Y:2016 | 11 | 2016 | OPTIMIZE PLANT POWER FACTOR | $7,251 | $25,830 | Implemented |
UK1513 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $1,818 | $4,620 | Implemented |
UK1513 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $363 | $747 | Implemented |
UK1513 # 03 Y:2015 | 03 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $284 | $0 | Implemented |
UK1513 # 04 Y:2015 | 04 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,053 | $0 | Implemented |
UK1513 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,440 | $1,500 | Implemented |
UK1513 # 06 Y:2015 | 06 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $12,766 | $14,063 | Implemented |
UK1513 # 07 Y:2015 | 07 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,363 | $440 | Implemented |
UK1513 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,883 | $1,750 | Implemented |
UK1513 # 09 Y:2015 | 09 | 2015 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,308 | $8,000 | Not Implemented |
UK1513 # 10 Y:2015 | 10 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,629 | $4,340 | Implemented |
UK1513 # 11 Y:2015 | 11 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $13,743 | $10,894 | Implemented |
UK1513 # 12 Y:2015 | 12 | 2015 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $970 | $540 | Not Implemented |
WV0492 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,061 | $1,700 | Implemented |
WV0492 # 02 Y:2014 | 02 | 2014 | COVER OPEN TANKS | $7,268 | $1,145 | Implemented |
WV0492 # 03 Y:2014 | 03 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,370 | $0 | Not Implemented |
WV0492 # 04 Y:2014 | 04 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $5,334 | $11,360 | Not Implemented |
WV0492 # 05 Y:2014 | 05 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,126 | $3,000 | Implemented |
WV0492 # 06 Y:2014 | 06 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,774 | $8,160 | Implemented |