Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
487
matching recommendationsNAICS | 33272 | Turned Product and Screw, Nut, and Bolt Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0363 # 12 Y:2013 | 12 | 2013 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $29,646 | $29,648 | Not Implemented |
SU0342 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,615 | $620 | Not Implemented |
SU0342 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $209 | $92 | Not Implemented |
SU0342 # 03 Y:2013 | 03 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $211 | $914 | Not Implemented |
SU0342 # 04 Y:2013 | 04 | 2013 | UPGRADE OBSOLETE EQUIPMENT | $344 | $1,388 | Implemented |
LL0344 # 01 Y:2011 | 01 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $15,757 | $630 | Implemented |
LL0344 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,150 | $1,360 | Implemented |
LL0344 # 03 Y:2011 | 03 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,859 | $210 | Implemented |
LL0344 # 04 Y:2011 | 04 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,425 | $575 | Implemented |
LL0344 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $699 | $480 | Implemented |
LL0344 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $151 | $156 | Not Implemented |
BD0386 # 01 Y:2011 | 01 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $19,582 | $16,000 | Not Implemented |
BD0386 # 02 Y:2011 | 02 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $19,115 | $86,640 | Not Implemented |
BD0386 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,419 | $28,476 | Implemented |
BD0386 # 04 Y:2011 | 04 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $11,046 | $40,000 | Not Implemented |
BD0386 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,230 | $3,000 | Implemented |
BD0386 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,692 | $3,000 | Implemented |
BD0386 # 07 Y:2011 | 07 | 2011 | USE SYNTHETIC LUBRICANT | $4,056 | $1,500 | Implemented |
BD0386 # 08 Y:2011 | 08 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,153 | $6,680 | Implemented |
BD0386 # 09 Y:2011 | 09 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,876 | $4,500 | Implemented |
BD0386 # 10 Y:2011 | 10 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,306 | $50 | Not Implemented |
BD0386 # 11 Y:2011 | 11 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,916 | $850 | Implemented |
BD0386 # 12 Y:2011 | 12 | 2011 | INSTALL OCCUPANCY SENSORS | $479 | $450 | Implemented |
BD0386 # 13 Y:2011 | 13 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $221 | $285 | Implemented |
BD0386 # 14 Y:2011 | 14 | 2011 | USE EVAPORATION TO CONCENTRATE MATERIAL | $6,567 | $10,000 | Implemented |