Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,747
matching recommendationsNAICS | 3328 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0372 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $10,159 | $500 | Implemented |
UM0372 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $9,602 | $2,472 | Implemented |
UM0372 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $2,083 | $2,500 | Implemented |
UM0372 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $25,000 | Implemented |
MA0665 # 01 Y:2010 | 01 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $15,680 | $58,600 | Implemented |
MA0665 # 02 Y:2010 | 02 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,642 | $18,330 | Implemented |
MA0665 # 03 Y:2010 | 03 | 2010 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,625 | $2,000 | Not Implemented |
MA0665 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,470 | $200 | Implemented |
MA0665 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $1,134 | $3,150 | Not Implemented |
MA0665 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,028 | $480 | Implemented |
MA0665 # 07 Y:2010 | 07 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $155 | $180 | Implemented |
MA0663 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,896 | $90,000 | Not Implemented |
MA0663 # 02 Y:2010 | 02 | 2010 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $10,239 | $24,000 | Not Implemented |
MA0663 # 03 Y:2010 | 03 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,990 | $21,410 | Not Implemented |
MA0663 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $938 | $600 | Implemented |
MA0663 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $900 | $200 | Not Implemented |
WV0406 # 01 Y:2010 | 01 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $165,791 | $87,000 | Not Implemented |
WV0406 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $75,243 | $91,000 | Not Implemented |
WV0406 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,098 | $49,200 | Implemented |
WV0406 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,356 | $7,809 | Not Implemented |
WV0406 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,767 | $65 | Not Implemented |
WV0406 # 06 Y:2010 | 06 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,089 | $245 | Not Implemented |
LL0328 # 01 Y:2010 | 01 | 2010 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $26,498 | $304 | Implemented |
LL0328 # 02 Y:2010 | 02 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,654 | $3,600 | Implemented |
LL0328 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,572 | $2,800 | Implemented |