261
matching recommendationsNAICS | 3328 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0826 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,622 | $2,500 | Implemented |
UD0826 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,036 | $2,500 | Implemented |
UD0826 # 03 Y:2010 | 03 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $978 | $60 | Implemented |
UD0826 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,213 | $35,000 | Implemented |
UD0826 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $788 | $2,200 | Implemented |
UD0826 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $337 | $1,750 | Not Implemented |
UD0826 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $51,028 | $24,300 | Not Implemented |
UD0826 # 08 Y:2010 | 08 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $10,244 | $2,000 | Not Implemented |
UD0826 # 09 Y:2010 | 09 | 2010 | INSULATE BARE EQUIPMENT | $5,734 | $1,600 | Implemented |
UD0826 # 10 Y:2010 | 10 | 2010 | INSULATE BARE EQUIPMENT | $3,846 | $23,040 | Not Implemented |
UM0372 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $2,083 | $2,500 | Implemented |
UM0372 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $25,000 | Implemented |
UM0372 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $265 | $2,000 | Implemented |
UM0372 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $645 | $200 | Implemented |
UM0372 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $88 | $1,000 | Implemented |
UM0372 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,702 | $3,500 | Implemented |
UM0372 # 07 Y:2010 | 07 | 2010 | COVER OPEN TANKS | $17,216 | $7,182 | Implemented |
UM0372 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $10,159 | $500 | Implemented |
UM0372 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $9,602 | $2,472 | Implemented |
UM0308 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,769 | $500 | Implemented |
UM0308 # 02 Y:2006 | 02 | 2006 | REDUCE VENTILATION AIR | $2,507 | $500 | Implemented |
UM0308 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,070 | $1,250 | Not Implemented |
UM0308 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,462 | $3,479 | Not Implemented |
UM0308 # 05 Y:2006 | 05 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $536 | $300 | Implemented |
UM0308 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $392 | $1,000 | Implemented |