Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
77
matching recommendationsNAICS | 33281 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0558 # 01 Y:2004 | 01 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $28,200 | $4,500 | Implemented |
MA0558 # 02 Y:2004 | 02 | 2004 | USE MINIMUM STEAM OPERATING PRESSURE | $19,575 | $1,000 | Not Implemented |
MA0558 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $12,830 | $5,000 | Implemented |
MA0558 # 04 Y:2004 | 04 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,494 | $4,680 | Implemented |
MA0558 # 06 Y:2004 | 06 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,912 | $0 | Implemented |
MA0558 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,965 | $2,690 | Implemented |
MA0558 # 08 Y:2004 | 08 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $979 | $240 | Not Implemented |
MA0558 # 05 Y:2004 | 05 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,990 | $0 | Not Implemented |
MA0551 # 04 Y:2004 | 04 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,302 | $4,680 | Implemented |
MA0551 # 01 Y:2004 | 01 | 2004 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $36,008 | $0 | Implemented |
MA0551 # 02 Y:2004 | 02 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $13,353 | $27,860 | Implemented |
MA0551 # 03 Y:2004 | 03 | 2004 | REDUCE VENTILATION AIR | $10,267 | $4,614 | Not Implemented |
MA0551 # 05 Y:2004 | 05 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,941 | $138 | Implemented |
MA0551 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,601 | $850 | Implemented |
MA0551 # 07 Y:2004 | 07 | 2004 | PAY BILLS ON TIME TO AVOID LATE FEES | $2,179 | $0 | Implemented |
MA0551 # 08 Y:2004 | 08 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,078 | $173 | Not Implemented |
MA0551 # 09 Y:2004 | 09 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $958 | $1,020 | Implemented |
MA0551 # 10 Y:2004 | 10 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $885 | $50 | Implemented |
MA0548 # 01 Y:2004 | 01 | 2004 | REDUCE VENTILATION AIR | $13,881 | $4,244 | Not Implemented |
MA0548 # 09 Y:2004 | 09 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $414 | $200 | Not Implemented |
MA0548 # 08 Y:2004 | 08 | 2004 | REDUCE VENTILATION AIR | $607 | $1,831 | Not Implemented |
MA0548 # 07 Y:2004 | 07 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $653 | $200 | Not Implemented |
MA0548 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $699 | $3,574 | Not Implemented |
MA0548 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $1,528 | $1,625 | Not Implemented |
MA0548 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $4,665 | $1,100 | Implemented |