Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0063 # 06 Y:2011 | 06 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,516 | $4,000 | Not Implemented |
TT0063 # 07 Y:2011 | 07 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,424 | $120 | Not Implemented |
LL0324 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $158 | $1,435 | Not Implemented |
LL0324 # 01 Y:2009 | 01 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $51,066 | $5,850 | Implemented |
LL0324 # 02 Y:2009 | 02 | 2009 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,552 | $1,140 | Not Implemented |
LL0324 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,908 | $265 | Not Implemented |
LL0324 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,689 | $1,050 | Not Implemented |
LL0324 # 05 Y:2009 | 05 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,089 | $1,246 | Not Implemented |
LL0324 # 06 Y:2009 | 06 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $258 | $120 | Not Implemented |
LL0324 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $142 | $270 | Not Implemented |
LL0171 # 06 Y:2003 | 06 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,125 | $318 | Implemented |
LL0171 # 05 Y:2003 | 05 | 2003 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $1,170,000 | $15,240 | Implemented |
LL0171 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,189 | $1,050 | Implemented |
LL0171 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,316 | $270 | Implemented |
LL0171 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $3,678 | $364 | Not Implemented |
LL0171 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,294 | $4,920 | Implemented |