Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
108
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0067 # 08 Y:2016 | 08 | 2016 | RECYCLE WHITE WATER | $18,931 | $7,044 | Not Implemented |
IP0067 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $12,719 | $2,549 | Not Implemented |
IP0067 # 10 Y:2016 | 10 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,775 | $15,000 | Not Implemented |
IP0067 # 14 Y:2016 | 14 | 2016 | INSULATE BARE EQUIPMENT | $40 | $167 | Implemented |
IP0067 # 15 Y:2016 | 15 | 2016 | COVER OPEN TANKS | $578 | $2,692 | Not Implemented |
IP0067 # 11 Y:2016 | 11 | 2016 | OPTIMIZE PLANT POWER FACTOR | $5,105 | $12,251 | Not Implemented |
IP0067 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,092 | $5 | Not Implemented |
IP0067 # 03 Y:2016 | 03 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,360 | $3 | Implemented |
IP0067 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,858 | $765 | Implemented |
IP0067 # 05 Y:2016 | 05 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $35,374 | $3,150 | Implemented |
IP0067 # 13 Y:2016 | 13 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,007 | $58,641 | Not Implemented |
IP0067 # 12 Y:2016 | 12 | 2016 | APPLY FOR INVESTMENT INCENTIVES | $4,112 | $10,000 | Implemented |
IP0067 # 09 Y:2016 | 09 | 2016 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $8,382 | $11,725 | Not Implemented |
IP0059 # 04 Y:2016 | 04 | 2016 | APPLY FOR INVESTMENT INCENTIVES | $1,633 | $2,000 | Not Implemented |
IP0059 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $1,345 | $3,616 | Implemented |
IP0059 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $257 | $776 | Not Implemented |
IP0059 # 02 Y:2016 | 02 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,602 | $99 | Implemented |
IP0059 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,353 | $58 | Implemented |
IP0059 # 03 Y:2016 | 03 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $76 | $62 | Implemented |
IP0057 # 13 Y:2016 | 13 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $440 | Implemented |
IP0057 # 14 Y:2016 | 14 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,183 | $7,207 | Not Implemented |
IP0057 # 09 Y:2016 | 09 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $927 | $200 | Implemented |
IP0057 # 05 Y:2016 | 05 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $401 | $20 | Not Implemented |
IP0057 # 07 Y:2016 | 07 | 2016 | INSTALL OCCUPANCY SENSORS | $5,533 | $807 | Not Implemented |
IP0057 # 15 Y:2016 | 15 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $464 | $1,038 | Not Implemented |