Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
897
matching recommendationsNAICS | 332999 | All Other Miscellaneous Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0273 # 05 Y:2007 | 05 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $313 | $623 | Not Implemented |
LL0273 # 06 Y:2007 | 06 | 2007 | INSTALL OCCUPANCY SENSORS | $59 | $60 | Not Implemented |
LL0273 # 07 Y:2007 | 07 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,340 | $1,318 | Not Implemented |
IA0402 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,419 | $512 | Implemented |
IA0402 # 02 Y:2007 | 02 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,179 | $1,720 | Implemented |
IA0402 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,343 | $44,874 | Implemented |
IA0402 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $993 | $6,575 | Implemented |
IA0402 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,589 | $7,711 | Implemented |
IA0402 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $116 | $158 | Implemented |
IA0402 # 07 Y:2007 | 07 | 2007 | COVER OPEN TANKS | $6,793 | $599 | Implemented |
IA0402 # 08 Y:2007 | 08 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $229 | $137 | Implemented |
IA0402 # 09 Y:2007 | 09 | 2007 | ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES | $765 | $667 | Implemented |
IA0402 # 10 Y:2007 | 10 | 2007 | INSULATE BARE EQUIPMENT | $2,271 | $3,989 | Not Implemented |
IA0402 # 11 Y:2007 | 11 | 2007 | REDUCE VENTILATION AIR | $38,317 | $10,141 | Implemented |
IA0402 # 12 Y:2007 | 12 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,070 | $3,770 | Implemented |
UF0386 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,441 | $4,440 | Not Implemented |
UF0386 # 02 Y:2006 | 02 | 2006 | ADD AREA LIGHTING SWITCHES | $5,721 | $13,094 | Not Implemented |
UF0386 # 03 Y:2006 | 03 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,878 | $0 | Not Implemented |
UF0386 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,880 | $56 | Not Implemented |
UF0386 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $1,101 | $1,703 | Not Implemented |
UF0386 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,727 | $1,457 | Not Implemented |
UF0386 # 07 Y:2006 | 07 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $811 | $0 | Not Implemented |
UF0386 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $711 | $0 | Not Implemented |
UF0386 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $212 | $0 | Not Implemented |
UF0386 # 10 Y:2006 | 10 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $4,883 | $846 | Not Implemented |