Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
897
matching recommendationsNAICS | 332999 | All Other Miscellaneous Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0264 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,356 | $1,624 | Not Implemented |
MS0264 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $989 | $944 | Not Implemented |
MS0264 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $183 | $249 | Not Implemented |
CO0555 # 01 Y:2004 | 01 | 2004 | REVISE SMOKE CLEANUP FROM OPERATIONS | $4,790 | $13,100 | Implemented |
CO0555 # 02 Y:2004 | 02 | 2004 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $900 | $580 | Implemented |
CO0555 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $186 | $260 | Implemented |
CO0555 # 04 Y:2004 | 04 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $220 | $420 | Not Implemented |
CO0555 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,890 | $37,430 | Not Implemented |
CO0555 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,540 | $4,990 | Not Implemented |
CO0555 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $120 | $390 | Not Implemented |
BD0273 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,813 | $3,470 | Implemented |
BD0273 # 02 Y:2004 | 02 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $10,682 | $50,000 | Implemented |
BD0273 # 03 Y:2004 | 03 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,786 | $3,000 | Implemented |
BD0273 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,606 | $4,270 | Implemented |
BD0273 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,942 | $255 | Implemented |
BD0273 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $2,608 | $1,725 | Implemented |
BD0273 # 07 Y:2004 | 07 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,185 | $2,900 | Implemented |
BD0273 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,098 | $0 | Implemented |
BD0273 # 09 Y:2004 | 09 | 2004 | USE PLASTIC PALLETS INSTEAD OF WOOD | $22,476 | $27,625 | Implemented |
BD0273 # 10 Y:2004 | 10 | 2004 | UTILIZE OUTSIDE CONTRACTING | $14,286 | $200 | Implemented |
BD0272 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $42,617 | $1,000 | Implemented |
BD0272 # 02 Y:2004 | 02 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $22,780 | $43,400 | Not Implemented |
BD0272 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,914 | $1,000 | Implemented |
BD0272 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,459 | $1,260 | Implemented |
BD0272 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,568 | $4,325 | Implemented |