Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0097 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,968 | $450 | Implemented |
MZ0097 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,420 | $2,000 | Not Implemented |
WV0456 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47,518 | $95,285 | Implemented |
WV0456 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,893 | $58,995 | Implemented |
WV0456 # 03 Y:2012 | 03 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,765 | $41,700 | Not Implemented |
WV0456 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,458 | $2,000 | Not Implemented |
WV0456 # 05 Y:2012 | 05 | 2012 | IMPROVE COMBUSTION CONTROL CAPABILITY | $11,368 | $38,096 | Not Implemented |
WV0456 # 06 Y:2012 | 06 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,618 | $33,940 | Not Implemented |
WV0456 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,729 | $12,395 | Implemented |
WV0456 # 08 Y:2012 | 08 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,545 | $7,380 | Not Implemented |
WV0456 # 09 Y:2012 | 09 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,207 | $5,050 | Not Implemented |
WV0456 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,040 | $2,069 | Implemented |
WV0456 # 11 Y:2012 | 11 | 2012 | IMPROVE LUBRICATION PRACTICES | $1,660 | $1,000 | Implemented |
WV0456 # 12 Y:2012 | 12 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,637 | $2,475 | Implemented |
WV0456 # 13 Y:2012 | 13 | 2012 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,180 | $1,000 | Implemented |
WV0456 # 14 Y:2012 | 14 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,129 | $555 | Implemented |
WV0456 # 15 Y:2012 | 15 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,089 | $981 | Implemented |
WV0456 # 16 Y:2012 | 16 | 2012 | USE PHOTOCELL CONTROLS | $824 | $705 | Implemented |
WV0454 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,085 | $108,401 | Not Implemented |
WV0454 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,088 | $7,920 | Not Implemented |
WV0454 # 03 Y:2012 | 03 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,992 | $13,611 | Not Implemented |
WV0454 # 04 Y:2012 | 04 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $3,789 | $19,607 | Not Implemented |
WV0454 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,331 | $11,667 | Not Implemented |
WV0454 # 06 Y:2012 | 06 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,836 | $775 | Implemented |
WV0454 # 07 Y:2012 | 07 | 2012 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,686 | $2,767 | Not Implemented |