Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0387 # 07 Y:2006 | 07 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $21,479 | $0 | Implemented |
UF0387 # 08 Y:2006 | 08 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,017 | $0 | Implemented |
UF0387 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,106 | $6,458 | Implemented |
UF0387 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $209 | $140 | Not Implemented |
UD0747 # 01 Y:2006 | 01 | 2006 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $182,400 | $85,000 | Not Implemented |
UD0747 # 02 Y:2006 | 02 | 2006 | DEVELOP STANDARD OPERATING PROCEDURES | $29,600 | $32,000 | Implemented |
UD0747 # 03 Y:2006 | 03 | 2006 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $23,000 | $1,200 | Not Implemented |
UD0747 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,997 | $22,960 | Not Implemented |
UD0747 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,322 | $14,256 | Implemented |
UD0747 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM THICKNESS INSULATION | $4,800 | $9,030 | Not Implemented |
UD0747 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $3,215 | $1,995 | Not Implemented |
UD0747 # 08 Y:2006 | 08 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $3,095 | $760 | Not Implemented |
UD0747 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,678 | $0 | Not Implemented |
UD0747 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,554 | $4,920 | Not Implemented |
UD0747 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,209 | $1,800 | Not Implemented |
UD0747 # 12 Y:2006 | 12 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $920 | $0 | Not Implemented |
UD0747 # 13 Y:2006 | 13 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $909 | $1,000 | Not Implemented |
UD0747 # 14 Y:2006 | 14 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $480 | $81 | Not Implemented |
IA0391 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,991 | $410 | Implemented |
IA0391 # 02 Y:2006 | 02 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $186 | $198 | Not Implemented |
IA0391 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $136 | $89 | Implemented |
IA0391 # 04 Y:2006 | 04 | 2006 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $3,433 | $1,735 | Implemented |
IA0391 # 05 Y:2006 | 05 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,668 | $12,865 | Not Implemented |
IA0391 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $5,577 | $349 | Not Implemented |
IA0391 # 07 Y:2006 | 07 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $804 | $600 | Implemented |