Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
194
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0432 # 02 Y:2011 | 02 | 2011 | REPAIR FAULTY LOUVERS AND DAMPERS | $7,824 | $2,500 | Implemented |
NC0432 # 03 Y:2011 | 03 | 2011 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $1,290 | $3,700 | Not Implemented |
NC0432 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,640 | $600 | Implemented |
NC0432 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $126 | $177 | Implemented |
NC0432 # 06 Y:2011 | 06 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,893 | $72,000 | Not Implemented |
NC0432 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,060 | $30,000 | Not Implemented |
NC0432 # 08 Y:2011 | 08 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,236 | $8,420 | Implemented |
NC0432 # 09 Y:2011 | 09 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $53,906 | $1,000 | Not Implemented |
NC0422 # 01 Y:2011 | 01 | 2011 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,623 | $1,000 | Not Implemented |
NC0422 # 02 Y:2011 | 02 | 2011 | REPLACE BOILER | $17,336 | $37,000 | Not Implemented |
NC0422 # 03 Y:2011 | 03 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,021 | $10,000 | Not Implemented |
NC0422 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,316 | $1,618 | Not Implemented |
NC0422 # 05 Y:2011 | 05 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,982 | $38,000 | Not Implemented |
NC0422 # 06 Y:2011 | 06 | 2011 | COVER OPEN TANKS | $11,237 | $15,000 | Not Implemented |
NC0422 # 07 Y:2011 | 07 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $15,795 | $1,500 | Not Implemented |
NC0422 # 08 Y:2011 | 08 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,815 | $22,930 | Not Implemented |
NC0422 # 09 Y:2011 | 09 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,211 | $100 | Not Implemented |
NC0422 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,027 | $100 | Not Implemented |
NC0422 # 11 Y:2011 | 11 | 2011 | PAY UTILITY BILLS ON TIME | $3,586 | $0 | Not Implemented |
NC0396 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $76,612 | $275,318 | Not Implemented |
NC0396 # 02 Y:2009 | 02 | 2009 | CONDENSE OPERATION INTO ONE BUILDING | $31,185 | $13,100 | Not Implemented |
NC0396 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,090 | $83,137 | Not Implemented |
NC0396 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $600 | $558 | Not Implemented |
NC0396 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $313 | $132 | Not Implemented |
NC0396 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,507 | $0 | Not Implemented |