Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
198
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0359 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,898 | $600 | Implemented |
SD0359 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,830 | $0 | Not Implemented |
SD0359 # 04 Y:2005 | 04 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,400 | $0 | Implemented |
SD0359 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,599 | $1,388 | Implemented |
SD0359 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,417 | $59,829 | Implemented |
SD0359 # 07 Y:2005 | 07 | 2005 | INSTALL SKYLIGHTS | $1,046 | $800 | Not Implemented |
SD0359 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $102 | $100 | Implemented |
SD0359 # 09 Y:2005 | 09 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $8,102 | $0 | Not Implemented |
SD0359 # 10 Y:2005 | 10 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,882 | $0 | Implemented |
SF0299 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,880 | $720 | Not Implemented |
SF0299 # 02 Y:2005 | 02 | 2005 | USE PHOTOCELL CONTROLS | $2,789 | $840 | Not Implemented |
SF0299 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,353 | $2,547 | Not Implemented |
SF0299 # 04 Y:2005 | 04 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,135 | $1,948 | Not Implemented |
SF0299 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $540 | $880 | Not Implemented |
SF0299 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,229 | $3,057 | Not Implemented |
SF0299 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,571 | $74,180 | Not Implemented |
SF0299 # 08 Y:2005 | 08 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,408 | $8,000 | Not Implemented |
LM0070 # 01 Y:2004 | 01 | 2004 | DISCONNECT BALLASTS | $4,442 | $0 | Implemented |
LM0070 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $1,970 | $110 | Implemented |
LM0070 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,542 | $1,950 | Not Implemented |
LM0070 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,020 | $1,000 | Implemented |
LM0070 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $486 | $0 | Implemented |
LM0070 # 06 Y:2004 | 06 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $3,254 | $3,050 | Not Implemented |
LM0070 # 07 Y:2004 | 07 | 2004 | MODIFY STARTUP/SHUTDOWN TIMES | $13,976 | $1,000 | Implemented |
LM0070 # 08 Y:2004 | 08 | 2004 | ELIMINATE SHIFT | $15,698 | $1,000 | Implemented |