Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
323
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0458 # 06 Y:2014 | 06 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $459 | $1,384 | Implemented |
SF0458 # 02 Y:2014 | 02 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,195 | $0 | Not Implemented |
SF0458 # 08 Y:2014 | 08 | 2014 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,900 | $0 | Implemented |
SF0458 # 03 Y:2014 | 03 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,339 | $0 | Implemented |
SF0458 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $1,683 | $6,142 | Not Implemented |
SF0458 # 01 Y:2014 | 01 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $6,859 | $840 | Implemented |
SF0458 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,813 | $30,411 | Not Implemented |
SF0458 # 09 Y:2014 | 09 | 2014 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,360 | $37,774 | Not Implemented |
SF0458 # 04 Y:2014 | 04 | 2014 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $1,582 | $522 | Implemented |
SU0374 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,770 | $2,000 | Implemented |
SU0374 # 01 Y:2014 | 01 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,507 | $0 | Not Implemented |
SU0374 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $5,979 | $616 | Not Implemented |
SU0374 # 06 Y:2014 | 06 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $931 | $2,604 | Implemented |
SU0374 # 07 Y:2014 | 07 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $161 | $615 | Not Implemented |
SU0374 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,433 | $39,216 | Not Implemented |
SU0374 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $379 | $276 | Implemented |
MI0269 # 06 Y:2014 | 06 | 2014 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,491 | $9,600 | Implemented |
MI0269 # 13 Y:2014 | 13 | 2014 | INSTALL OCCUPANCY SENSORS | $51 | $80 | Implemented |
MI0269 # 11 Y:2014 | 11 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $928 | $1,660 | Implemented |
MI0269 # 10 Y:2014 | 10 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,064 | $360 | Implemented |
MI0269 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,598 | $2,160 | Implemented |
MI0269 # 05 Y:2014 | 05 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,528 | $2,040 | Implemented |
MI0269 # 08 Y:2014 | 08 | 2014 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,668 | $6,886 | Implemented |
MI0269 # 07 Y:2014 | 07 | 2014 | INSTALL SKYLIGHTS | $2,957 | $500 | Implemented |
MI0269 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,584 | $3,600 | Implemented |