IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

208

matching recommendations
Reset
NAICS 33331 Commercial and Service Industry Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0220 # 07 Y:2012 07 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,050 $200 Implemented
MI0220 # 11 Y:2012 11 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,014 $320 Implemented
MI0220 # 12 Y:2012 12 2012 INSTALL SKYLIGHTS $978 $1,920 Implemented
MI0220 # 13 Y:2012 13 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $906 $208 Implemented
OK0820 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,500 $16,200 Implemented
MI0217 # 01 Y:2012 01 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $18,962 $4,500 Implemented
MI0217 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,605 $39,990 Implemented
MI0217 # 03 Y:2012 03 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,727 $1,300 Implemented
MI0217 # 04 Y:2012 04 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $1,412 $900 Implemented
MI0217 # 05 Y:2012 05 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,064 $1,320 Implemented
UD0841 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $88,915 $80,000 Implemented
UD0841 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,283 $40,000 Implemented
UD0841 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,101 $30,000 Implemented
UD0841 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $43,664 $0 Implemented
UD0841 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,362 $500 Implemented
UD0841 # 10 Y:2011 10 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $42,803 $110,624 Implemented
UD0841 # 13 Y:2011 13 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $417 $1,012 Implemented
UD0841 # 14 Y:2011 14 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $64,796 $20,000 Implemented
UD0841 # 15 Y:2011 15 2011 ISOLATE HOT OR COLD EQUIPMENT $33,356 $2,000 Implemented
UD0841 # 17 Y:2011 17 2011 INSTALL AUTOMATIC STACK DAMPER $20,941 $600 Implemented
UD0841 # 18 Y:2011 18 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,133 $2,098 Implemented
LL0355 # 01 Y:2011 01 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $121,680 $22,440 Implemented
LL0355 # 02 Y:2011 02 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $7,278 $4,106 Implemented
LL0355 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,642 $1,680 Implemented
LL0355 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,751 $11,200 Implemented