Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
483
matching recommendationsNAICS | 33331 | Commercial and Service Industry Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0208 # 06 Y:2022 | 06 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $627 | $96 | Not Implemented |
DL0208 # 05 Y:2022 | 05 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $3,567 | $71 | Implemented |
DL0208 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $583 | $0 | Implemented |
DL0208 # 03 Y:2022 | 03 | 2022 | REDUCE VENTILATION AIR | $4,894 | $0 | Not Implemented |
DL0208 # 02 Y:2022 | 02 | 2022 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $8,504 | $0 | Not Implemented |
DL0208 # 01 Y:2022 | 01 | 2022 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $25,361 | $3,000 | Not Implemented |
LE0527 # 01 Y:2022 | 01 | 2022 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,805 | $0 | Implemented |
LE0527 # 02 Y:2022 | 02 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $103 | $40 | Not Implemented |
LE0527 # 03 Y:2022 | 03 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $2,621 | $1,330 | Implemented |
LE0527 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,500 | $3,435 | Implemented |
LE0527 # 05 Y:2022 | 05 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $32,527 | $500,000 | Implemented |
LE0527 # 06 Y:2022 | 06 | 2022 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,260 | $8,500 | Not Implemented |
LE0527 # 07 Y:2022 | 07 | 2022 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $16,154 | $160,000 | Implemented |
WM0168 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,833 | $15,082 | Implemented |
WM0168 # 02 Y:2021 | 02 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,941 | $0 | Implemented |
WM0168 # 03 Y:2021 | 03 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,669 | $37,278 | Not Implemented |
WM0168 # 04 Y:2021 | 04 | 2021 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $3,750 | $6,000 | Not Implemented |
WM0168 # 05 Y:2021 | 05 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,618 | $0 | Implemented |
WM0168 # 06 Y:2021 | 06 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,850 | $4,250 | Not Implemented |
WM0168 # 07 Y:2021 | 07 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $942 | $1,650 | Not Implemented |
WM0168 # 08 Y:2021 | 08 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $642 | $1,890 | Implemented |
WM0168 # 09 Y:2021 | 09 | 2021 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $433 | $1,490 | Not Implemented |
WM0168 # 10 Y:2021 | 10 | 2021 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $199 | $750 | Implemented |
AM0819 # 06 Y:2021 | 06 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $50 | $0 | Implemented |
AM0819 # 05 Y:2021 | 05 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $60 | $90 | Implemented |