Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsNAICS | 333314 | Optical Instrument and Lens Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0499 # 03 Y:2020 | 03 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,448 | $4,525 | Implemented |
SU0499 # 04 Y:2020 | 04 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $627 | $999 | Not Implemented |
SU0499 # 02 Y:2020 | 02 | 2020 | REDUCE VENTILATION AIR | $2,636 | $882 | Implemented |
SU0499 # 01 Y:2020 | 01 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,584 | $534 | Implemented |
MA0775 # 06 Y:2017 | 06 | 2017 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $708 | $412 | Not Implemented |
MA0775 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $28,320 | $16,929 | Not Implemented |
MA0775 # 02 Y:2017 | 02 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $20,697 | $100 | Implemented |
MA0775 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,966 | $20,488 | Not Implemented |
MA0775 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,486 | $21,000 | Not Implemented |
MA0775 # 03 Y:2017 | 03 | 2017 | AIR CONDITION ONLY SPACE NECESSARY | $13,365 | $7,900 | Not Implemented |
SU0442 # 09 Y:2017 | 09 | 2017 | UPGRADE OBSOLETE EQUIPMENT | $108 | $356 | Implemented |
SU0442 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $948 | $563 | Implemented |
SU0442 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,098 | $946 | Not Implemented |
SU0442 # 07 Y:2017 | 07 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,087 | $7,500 | Not Implemented |
SU0442 # 06 Y:2017 | 06 | 2017 | REDUCE VENTILATION AIR | $1,697 | $1,147 | Not Implemented |
SU0442 # 01 Y:2017 | 01 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,103 | $0 | Implemented |
SU0442 # 03 Y:2017 | 03 | 2017 | ELIMINATE/REDUCE AN OPERATION | $10,476 | $4,400 | Implemented |
SU0442 # 02 Y:2017 | 02 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,092 | $0 | Implemented |
SU0442 # 08 Y:2017 | 08 | 2017 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $74 | $208 | Implemented |
MA0770 # 04 Y:2017 | 04 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $286 | $20 | Not Implemented |
MA0770 # 02 Y:2017 | 02 | 2017 | AIR CONDITION ONLY SPACE NECESSARY | $2,351 | $1,000 | Not Implemented |
MA0770 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $124 | $100 | Implemented |
MA0770 # 01 Y:2017 | 01 | 2017 | REDUCE VENTILATION AIR | $8,661 | $1,503 | Not Implemented |
MA0770 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $1,809 | $2,784 | Implemented |
CO0697 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,440 | $5,180 | Not Implemented |