Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsNAICS | 3334 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0508 # 03 Y:2011 | 03 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $2,193 | $300 | Implemented |
SD0508 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $4,354 | $1,440 | Not Implemented |
SD0508 # 05 Y:2011 | 05 | 2011 | INSTALL SET-BACK TIMERS | $1,411 | $1,000 | Implemented |
SD0508 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45,218 | $46,656 | Not Implemented |
LM0062 # 12 Y:2003 | 12 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $505,164 | $0 | Implemented |
LM0062 # 11 Y:2003 | 11 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $17,820 | $3,000 | Implemented |
LM0062 # 10 Y:2003 | 10 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $105,000 | $17,500 | Implemented |
LM0062 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $711 | $724 | Implemented |
LM0062 # 02 Y:2003 | 02 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,246 | $0 | Implemented |
LM0062 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,003 | $6,290 | Implemented |
LM0062 # 09 Y:2003 | 09 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $52,500 | $19,910 | Implemented |
LM0062 # 08 Y:2003 | 08 | 2003 | AIR CONDITION ONLY SPACE NECESSARY | $17,255 | $0 | Implemented |
LM0062 # 07 Y:2003 | 07 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $666 | $750 | Not Implemented |
LM0062 # 06 Y:2003 | 06 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $3,170 | $1,950 | Not Implemented |
LM0062 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,369 | $410 | Implemented |
LM0062 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $415 | $219 | Implemented |