Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
951
matching recommendationsNAICS | 33341 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0796 # 08 Y:2010 | 08 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $786 | $1,850 | Implemented |
UD0822 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $609 | $609 | Not Implemented |
UD0822 # 02 Y:2010 | 02 | 2010 | INSTALL WIND POWERED ELECTRIC GENERATOR | $244,092 | $1,216,000 | Not Implemented |
UD0822 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,399 | $8,760 | Not Implemented |
UD0822 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,724 | $24,375 | Not Implemented |
UD0822 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $677 | $125 | Not Implemented |
UD0822 # 06 Y:2010 | 06 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,400 | $2,000 | Not Implemented |
UD0822 # 07 Y:2010 | 07 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,219 | $5,273 | Not Implemented |
UD0822 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,449 | $500 | Not Implemented |
UD0822 # 09 Y:2010 | 09 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $13,033 | $39,100 | Not Implemented |
UD0822 # 10 Y:2010 | 10 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,483 | $63 | Implemented |
UD0822 # 11 Y:2010 | 11 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,147 | $2,100 | Not Implemented |
UD0822 # 12 Y:2010 | 12 | 2010 | INSTALL FOSSIL FUEL MAKE-UP AIR UNIT | $1,500 | $14,900 | Not Implemented |
MS0349 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,903 | $31,050 | Implemented |
MS0349 # 02 Y:2010 | 02 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,920 | $140 | Not Implemented |
MS0349 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,685 | $389 | Implemented |
MS0349 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,399 | $671 | Not Implemented |
GT0864 # 01 Y:2009 | 01 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,717 | $0 | Not Implemented |
GT0864 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,440 | $3,700 | Not Implemented |
GT0864 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $17,020 | $31,520 | Not Implemented |
GT0864 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,083 | $90,000 | Not Implemented |
GT0864 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,718 | $61,839 | Not Implemented |
GT0864 # 06 Y:2009 | 06 | 2009 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $17,955 | $22,473 | Not Implemented |
GT0864 # 07 Y:2009 | 07 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $56,030 | $107,040 | Not Implemented |
MA0644 # 01 Y:2009 | 01 | 2009 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $34,492 | $160,000 | Implemented |