Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
958
matching recommendationsNAICS | 33341 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0692 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,577 | $11,882 | Implemented |
OK0692 # 11 Y:2004 | 11 | 2004 | INSTALL OCCUPANCY SENSORS | $1,911 | $1,690 | Not Implemented |
OK0691 # 01 Y:2004 | 01 | 2004 | INSTALL EQUIPMENT TO MOVE PRODUCT | $90,154 | $5,782 | Not Implemented |
OK0691 # 02 Y:2004 | 02 | 2004 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $270,439 | $2,825 | Implemented |
OK0691 # 03 Y:2004 | 03 | 2004 | INSTALL SET-BACK TIMERS | $6,531 | $3,832 | Implemented |
OK0691 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,036 | $559 | Implemented |
OK0691 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $265 | $0 | Implemented |
OK0691 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $254 | $760 | Not Implemented |
OK0691 # 07 Y:2004 | 07 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $886 | $139 | Implemented |
SU0188 # 01 Y:2004 | 01 | 2004 | ADVERTISE PRODUCT OR SERVICE | $10,418 | $0 | Implemented |
SU0188 # 02 Y:2004 | 02 | 2004 | PAY UTILITY BILLS ON TIME | $1,203 | $0 | Implemented |
SU0188 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $883 | $0 | Not Implemented |
SU0188 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $548 | $184 | Not Implemented |
SU0188 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $5,424 | $34,382 | Not Implemented |
OK0689 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,021 | $1,180 | Not Implemented |
OK0689 # 02 Y:2004 | 02 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $857 | $0 | Not Implemented |
OK0689 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $1,079 | $2,156 | Implemented |
OK0689 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,433 | $252 | Implemented |
OK0689 # 05 Y:2004 | 05 | 2004 | INSTALL SET-BACK TIMERS | $853 | $822 | Not Implemented |
OK0689 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,521 | $472 | Not Implemented |
OK0689 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,393 | $758 | Not Implemented |
BD0260 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,265 | $0 | Implemented |
BD0260 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,158 | $900 | Implemented |
BD0260 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $5,118 | $6,900 | Implemented |
BD0260 # 04 Y:2004 | 04 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,159 | $1,159 | Implemented |