Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
167
matching recommendationsNAICS | 333613 | Mechanical Power Transmission Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0845 # 01 Y:2022 | 01 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $108,785 | $906,122 | Not Implemented |
MA0845 # 06 Y:2022 | 06 | 2022 | INSULATE BARE EQUIPMENT | $6,066 | $2,910 | Not Implemented |
MA0845 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,754 | $14,292 | Implemented |
MA0845 # 05 Y:2022 | 05 | 2022 | ADJUST VENTS TO MINIMIZE ENERGY USE | $8,349 | $10,667 | Not Implemented |
MA0845 # 02 Y:2022 | 02 | 2022 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $26,668 | $60,000 | Implemented |
MA0845 # 03 Y:2022 | 03 | 2022 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,709 | $182,139 | Not Implemented |
MA0845 # 07 Y:2022 | 07 | 2022 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,762 | $505 | Not Implemented |
IC0265 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,312 | $7,533 | Implemented |
IC0265 # 02 Y:2022 | 02 | 2022 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $705 | $304 | Implemented |
IC0265 # 01 Y:2022 | 01 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,567 | $5,100 | Implemented |
IC0265 # 04 Y:2022 | 04 | 2022 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $19,650 | $2,435 | Not Implemented |
OK1073 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,707 | $1,176 | Implemented |
OK1073 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,161 | $9,927 | Implemented |
OK1073 # 02 Y:2022 | 02 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,548 | $12,334 | Not Implemented |
OK1073 # 01 Y:2022 | 01 | 2022 | OPTIMIZE PLANT POWER FACTOR | $32,771 | $39,489 | Not Implemented |
OK1073 # 05 Y:2022 | 05 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,129 | $0 | Implemented |
LE0486 # 04 Y:2019 | 04 | 2019 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $15,202 | $21,000 | Not Implemented |
LE0486 # 06 Y:2019 | 06 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,726 | $7,400 | Not Implemented |
LE0486 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,174 | $1,540 | Implemented |
LE0486 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $57,024 | $500 | Not Implemented |
LE0486 # 05 Y:2019 | 05 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,256 | $65,000 | Not Implemented |
LE0486 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,558 | $28,275 | Implemented |
LE0486 # 02 Y:2019 | 02 | 2019 | INSTALL TIMERS AND/OR THERMOSTATS | $8,764 | $720 | Implemented |
UA0153 # 02 Y:2016 | 02 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $25,593 | $4,000 | Implemented |
UA0153 # 01 Y:2016 | 01 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $73,794 | $99,000 | Not Implemented |