IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,619

matching recommendations
Reset
NAICS 3339 Other General Purpose Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0343 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $125 $70 Implemented
IA0343 # 04 Y:2004 04 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,173 $7,306 Implemented
IA0343 # 05 Y:2004 05 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $817 $1,230 Not Implemented
IA0343 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $8,859 $9,696 Not Implemented
IA0343 # 07 Y:2004 07 2004 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $39,733 $10,000 Implemented
MS0253 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,032 $11 Not Implemented
MS0253 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,649 $4,689 Not Implemented
MS0253 # 03 Y:2004 03 2004 USE RADIANT HEATER FOR SPOT HEATING $1,526 $4,000 Implemented
MS0253 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $853 $288 Implemented
MS0253 # 05 Y:2004 05 2004 BURN WASTE OIL FOR HEAT $703 $2,190 Not Implemented
MS0253 # 06 Y:2004 06 2004 INSTALL TIMERS AND/OR THERMOSTATS $480 $708 Not Implemented
MS0253 # 07 Y:2004 07 2004 CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING $336 $68 Not Implemented
MS0253 # 08 Y:2004 08 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $198 $735 Implemented
NC0286 # 01 Y:2004 01 2004 ADD ADDITIONAL PRODUCTION SHIFT $130,000 $20,000 Not Implemented
NC0286 # 02 Y:2004 02 2004 REDUCE VENTILATION AIR $12,177 $35,730 Implemented
NC0286 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,904 $100 Implemented
NC0286 # 04 Y:2004 04 2004 UPGRADE CONTROLS ON COMPRESSORS $1,892 $2,000 Implemented
NC0286 # 05 Y:2004 05 2004 UPGRADE CONTROLS ON COMPRESSORS $1,512 $4,600 Not Implemented
NC0286 # 06 Y:2004 06 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,566 $6,500 Not Implemented
NC0286 # 07 Y:2004 07 2004 DEVELOP A REPAIR/REPLACE POLICY $175 $169 Implemented
NC0286 # 08 Y:2004 08 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,019 $100 Not Implemented
NC0286 # 09 Y:2004 09 2004 INSTALL OCCUPANCY SENSORS $247 $191 Implemented
NC0286 # 10 Y:2004 10 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $61 $70 Not Implemented
TA0074 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,000 $14,432 Not Implemented
TA0074 # 02 Y:2004 02 2004 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,340 $72 Not Implemented