matching recommendationsNAICS | 33391 | Pump and Compressor Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0587 # 02 Y:2017 | 02 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $375 | $75 | Not Implemented |
NC0587 # 03 Y:2017 | 03 | 2017 | INSTALL OCCUPANCY SENSORS | $798 | $400 | Implemented |
NC0587 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $62,705 | $158,000 | Not Implemented |
NC0587 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,666 | $500 | Implemented |
NC0587 # 06 Y:2017 | 06 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,022 | $1,200 | Implemented |
NC0587 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $64,592 | $221,073 | Implemented |
NC0422 # 11 Y:2011 | 11 | 2011 | PAY UTILITY BILLS ON TIME | $3,586 | $0 | Not Implemented |
NC0422 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,027 | $100 | Not Implemented |
NC0422 # 09 Y:2011 | 09 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,211 | $100 | Not Implemented |
NC0422 # 08 Y:2011 | 08 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,815 | $22,930 | Not Implemented |
NC0422 # 07 Y:2011 | 07 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $15,795 | $1,500 | Not Implemented |
NC0422 # 06 Y:2011 | 06 | 2011 | COVER OPEN TANKS | $11,237 | $15,000 | Not Implemented |
NC0422 # 05 Y:2011 | 05 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,982 | $38,000 | Not Implemented |
NC0422 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,316 | $1,618 | Not Implemented |
NC0422 # 03 Y:2011 | 03 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,021 | $10,000 | Not Implemented |
NC0422 # 02 Y:2011 | 02 | 2011 | REPLACE BOILER | $17,336 | $37,000 | Not Implemented |
NC0422 # 01 Y:2011 | 01 | 2011 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,623 | $1,000 | Not Implemented |
NC0369 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $1,564 | Not Implemented |
NC0369 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,862 | $0 | Not Implemented |
NC0369 # 07 Y:2007 | 07 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $968 | $2,159 | Not Implemented |
NC0369 # 06 Y:2007 | 06 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,730 | $0 | Implemented |
NC0369 # 05 Y:2007 | 05 | 2007 | KEEP BOILER TUBES CLEAN | $2,955 | $1,000 | Implemented |
NC0369 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,910 | $100 | Implemented |
NC0369 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,420 | $1,500 | Implemented |
NC0369 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,750 | $13,500 | Implemented |