Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsNAICS | 33392 | Material Handling Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0240 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,534 | $37,977 | Not Implemented |
MS0240 # 01 Y:2003 | 01 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $47,808 | $4,800 | Not Implemented |
MS0240 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $156 | $260 | Not Implemented |
MS0240 # 10 Y:2003 | 10 | 2003 | DISCONNECT BALLASTS | $198 | $180 | Implemented |
MS0240 # 09 Y:2003 | 09 | 2003 | USE SYNTHETIC LUBRICANT | $846 | $213 | Not Implemented |
MS0240 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,629 | $1,062 | Not Implemented |
MS0240 # 07 Y:2003 | 07 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,855 | $827 | Implemented |
MS0240 # 06 Y:2003 | 06 | 2003 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,995 | $528 | Implemented |
MS0240 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,210 | $228 | Implemented |
MS0240 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $15,997 | $980 | Implemented |
MS0240 # 03 Y:2003 | 03 | 2003 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $18,919 | $2,010 | Not Implemented |
OK0675 # 11 Y:2003 | 11 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $668 | $287 | Not Implemented |
OK0675 # 10 Y:2003 | 10 | 2003 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $61,378 | $3,000 | Not Implemented |
OK0675 # 03 Y:2003 | 03 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,171 | $2,000 | Implemented |
OK0675 # 09 Y:2003 | 09 | 2003 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $14,350 | $23,640 | Not Implemented |
OK0675 # 08 Y:2003 | 08 | 2003 | INSTALL SET-BACK TIMERS | $1,993 | $0 | Not Implemented |
OK0675 # 07 Y:2003 | 07 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,672 | $2,173 | Not Implemented |
OK0675 # 06 Y:2003 | 06 | 2003 | OPTIMIZE PLANT POWER FACTOR | $428 | $2,730 | Not Implemented |
OK0675 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $565 | $367 | Implemented |
OK0675 # 04 Y:2003 | 04 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,210 | $2,000 | Not Implemented |
OK0675 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $124 | $231 | Not Implemented |
OK0675 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $274 | $256 | Implemented |
UD0676 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $19,216 | $6,000 | Implemented |
UD0676 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,997 | $5,000 | Not Implemented |
UD0676 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,900 | $0 | Not Implemented |