IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

73

matching recommendations
Reset
NAICS 333921 Elevator and Moving Stairway Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0278 # 07 Y:2008 07 2008 RECOVER WASTE HEAT FROM EQUIPMENT $6,783 $7,000 Not Implemented
LE0278 # 14 Y:2008 14 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $52,373 $142,010 Implemented
LE0278 # 12 Y:2008 12 2008 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,387 $3,290 Not Implemented
LE0278 # 11 Y:2008 11 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,195 $1,824 Implemented
LE0278 # 10 Y:2008 10 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,764 $800 Not Implemented
LE0278 # 09 Y:2008 09 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,894 $304 Not Implemented
LE0278 # 08 Y:2008 08 2008 USE OPTIMUM TEMPERATURE $7,669 $500 Not Implemented
UD0724 # 08 Y:2005 08 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,477 $0 Not Implemented
UD0724 # 09 Y:2005 09 2005 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $3,364 $0 Implemented
UD0724 # 10 Y:2005 10 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,915 $0 Not Implemented
UD0724 # 11 Y:2005 11 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $471 $880 Implemented
UD0724 # 01 Y:2005 01 2005 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $59,198 $30,000 Not Implemented
UD0724 # 07 Y:2005 07 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,199 $7,500 Not Implemented
UD0724 # 06 Y:2005 06 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,922 $4,800 Not Implemented
UD0724 # 05 Y:2005 05 2005 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $9,550 $530 Not Implemented
UD0724 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $13,563 $6,505 Implemented
UD0724 # 03 Y:2005 03 2005 USE PHOTOCELL CONTROLS $16,400 $0 Implemented
UD0724 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,240 $102,000 Not Implemented
MI0072 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $1,447 $800 Implemented
MI0072 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $-2,108 $550 Implemented
MI0072 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,341 $228 Implemented
MI0072 # 04 Y:2004 04 2004 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING $221,675 $0 Implemented
MI0072 # 05 Y:2004 05 2004 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $16,550 $2,176 Not Implemented