Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
718
matching recommendationsNAICS | 33399 | All Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0260 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $816 | $200 | Not Implemented |
LE0260 # 09 Y:2007 | 09 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $234 | $500 | Not Implemented |
LE0260 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,501 | $54,052 | Not Implemented |
UD0758 # 01 Y:2007 | 01 | 2007 | REDUCE VENTILATION AIR | $24,896 | $0 | Implemented |
UD0758 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,028 | $36,900 | Not Implemented |
UD0758 # 03 Y:2007 | 03 | 2007 | USE POWER DURING OFF-PEAK PERIODS | $12,438 | $0 | Not Implemented |
UD0758 # 04 Y:2007 | 04 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $10,225 | $15,000 | Not Implemented |
UD0758 # 05 Y:2007 | 05 | 2007 | USE MINIMUM SAFE OVEN VENTILATION | $9,717 | $595 | Not Implemented |
UD0758 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,786 | $0 | Not Implemented |
UD0758 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,657 | $0 | Implemented |
UD0758 # 08 Y:2007 | 08 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,876 | $2,500 | Implemented |
UD0758 # 09 Y:2007 | 09 | 2007 | OPTIMIZE PLANT POWER FACTOR | $992 | $3,000 | Not Implemented |
UD0758 # 10 Y:2007 | 10 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $876 | $144 | Implemented |
UD0758 # 11 Y:2007 | 11 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $538 | $0 | Not Implemented |
UD0758 # 12 Y:2007 | 12 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $430 | $0 | Implemented |
UD0758 # 13 Y:2007 | 13 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $320 | $200 | Not Implemented |
OK0743 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,720 | $5,010 | Implemented |
OK0743 # 02 Y:2007 | 02 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,189 | $569 | Implemented |
OK0743 # 03 Y:2007 | 03 | 2007 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $642 | $6,000 | Implemented |
OK0743 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,598 | $3,500 | Implemented |
OK0743 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $21,613 | $2,450 | Implemented |
OK0743 # 06 Y:2007 | 06 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $24,607 | $0 | Not Implemented |
OK0743 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $5,413 | $723 | Implemented |
OR0513 # 01 Y:2007 | 01 | 2007 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $13,700 | $5,000 | Implemented |
OR0513 # 02 Y:2007 | 02 | 2007 | USE PHOTOCELL CONTROLS | $5,900 | $8,000 | Not Implemented |