Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,029
matching recommendationsNAICS | 334 | Computer and Electronic Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MUCM29 # 03 Y:2025 | 03 | 2025 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $181 | $0 | n/a |
MUCM29 # 06 Y:2025 | 06 | 2025 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,198 | $5,875 | n/a |
MUCM29 # 01 Y:2025 | 01 | 2025 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $3,489 | $1,000 | n/a |
MUCM29 # 07 Y:2025 | 07 | 2025 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $80 | $125 | n/a |
MUCM29 # 04 Y:2025 | 04 | 2025 | USE PHOTOCELL CONTROLS | $380 | $834 | n/a |
MUCM29 # 02 Y:2025 | 02 | 2025 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,011 | $36,390 | n/a |
MUCM29 # 05 Y:2025 | 05 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $486 | $179 | n/a |
UD1118 # 01 Y:2025 | 01 | 2025 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,142 | $0 | n/a |
UD1118 # 03 Y:2025 | 03 | 2025 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,394 | $1,740 | n/a |
UD1118 # 02 Y:2025 | 02 | 2025 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,958 | $0 | n/a |
UD1118 # 05 Y:2025 | 05 | 2025 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $723 | $2,030 | n/a |
UD1118 # 04 Y:2025 | 04 | 2025 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $894 | $0 | n/a |
UD1118 # 07 Y:2025 | 07 | 2025 | INSTALL OCCUPANCY SENSORS | $186 | $153 | n/a |
UD1118 # 06 Y:2025 | 06 | 2025 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $23,759 | $18,000 | n/a |
MS0450 # 03 Y:2025 | 03 | 2025 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $9,485 | $0 | n/a |
MS0450 # 06 Y:2025 | 06 | 2025 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,775 | $1,740 | n/a |
MS0450 # 04 Y:2025 | 04 | 2025 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $14,625 | $43,769 | n/a |
MS0450 # 05 Y:2025 | 05 | 2025 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,199 | $5,414 | n/a |
MS0450 # 02 Y:2025 | 02 | 2025 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $44,435 | $122,808 | n/a |
MS0450 # 01 Y:2025 | 01 | 2025 | AIR CONDITION ONLY SPACE NECESSARY | $16,450 | $19,723 | n/a |
UC2509 # 03 Y:2024 | 03 | 2024 | OPTIMIZE PLANT POWER FACTOR | $19,546 | $32,370 | n/a |
UC2509 # 05 Y:2024 | 05 | 2024 | REPLACE BOILER | $42,258 | $132,297 | n/a |
UC2509 # 02 Y:2024 | 02 | 2024 | PAY UTILITY BILLS ON TIME | $114 | $0 | n/a |
UC2509 # 01 Y:2024 | 01 | 2024 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $28,237 | $0 | n/a |
UC2509 # 04 Y:2024 | 04 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,936 | $100 | n/a |