Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsNAICS | 334 | Computer and Electronic Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0450 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,110 | $0 | Not Implemented |
UF0450 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,031 | $0 | Not Implemented |
UF0450 # 06 Y:2011 | 06 | 2011 | USE COMPRESSOR AIR FILTERS | $2,246 | $270 | Not Implemented |
UF0450 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,013 | $5,903 | Not Implemented |
UF0450 # 08 Y:2011 | 08 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,431 | $0 | Not Implemented |
UF0450 # 09 Y:2011 | 09 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,074 | $3,066 | Not Implemented |
UF0450 # 10 Y:2011 | 10 | 2011 | AIR CONDITION ONLY SPACE NECESSARY | $204 | $17 | Not Implemented |
UF0450 # 11 Y:2011 | 11 | 2011 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,406 | $109 | Not Implemented |
MI0203 # 01 Y:2011 | 01 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $16,812 | $34,688 | Implemented |
MI0203 # 02 Y:2011 | 02 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,265 | $2,500 | Implemented |
MI0203 # 03 Y:2011 | 03 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $8,406 | $12,400 | Not Implemented |
MI0203 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,489 | $5,225 | Implemented |
MI0203 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,157 | $50 | Implemented |
MI0203 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,006 | $1,320 | Implemented |
UF0428 # 01 Y:2009 | 01 | 2009 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $1,734 | $0 | Implemented |
UF0428 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,365 | $0 | Implemented |
UF0428 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,980 | $5,895 | Implemented |
UF0428 # 04 Y:2009 | 04 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,371 | $2,260 | Not Implemented |
UF0428 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $872 | $1,971 | Implemented |
UF0428 # 06 Y:2009 | 06 | 2009 | INSTALL COMMON HEADER ON COMPRESSORS | $674 | $0 | Not Implemented |
UF0428 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,285 | $0 | Implemented |
UF0428 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $44,818 | $3,326 | Not Implemented |
UF0428 # 09 Y:2009 | 09 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $25,086 | $0 | Implemented |
MI0186 # 01 Y:2009 | 01 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $160,282 | $0 | Implemented |
MI0186 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $110,625 | $4,000 | Implemented |