Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,581
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2203 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $3,397 | $1,678 | Not Implemented |
UW2203 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,676 | $7,295 | Not Implemented |
UW2203 # 05 Y:2022 | 05 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $262,732 | $1,628,434 | Not Implemented |
SF0585 # 01 Y:2022 | 01 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,341 | $0 | Implemented |
SF0585 # 02 Y:2022 | 02 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,174 | $2,893 | Implemented |
SF0585 # 03 Y:2022 | 03 | 2022 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $23,840 | $8,000 | Not Implemented |
SF0585 # 04 Y:2022 | 04 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $897 | $400 | Implemented |
SF0585 # 05 Y:2022 | 05 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $3,867 | $8,345 | Implemented |
SF0585 # 06 Y:2022 | 06 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $95,415 | $561,099 | Not Implemented |
SF0585 # 07 Y:2022 | 07 | 2022 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $17,102 | $105,401 | Not Implemented |
OK1071 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,382 | $61,013 | Implemented |
OK1071 # 02 Y:2022 | 02 | 2022 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $12,657 | $10,000 | Not Implemented |
OK1071 # 03 Y:2022 | 03 | 2022 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,419 | $0 | Not Implemented |
OK1071 # 04 Y:2022 | 04 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,640 | $0 | Not Implemented |
DL0203 # 01 Y:2022 | 01 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,561 | $0 | Not Implemented |
DL0203 # 02 Y:2022 | 02 | 2022 | USE OPTIMUM TEMPERATURE | $309 | $0 | Not Implemented |
DL0203 # 03 Y:2022 | 03 | 2022 | UPGRADE CONTROLS ON COMPRESSORS | $4,027 | $31,018 | Not Implemented |
DL0203 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $179 | $0 | Not Implemented |
DL0203 # 05 Y:2022 | 05 | 2022 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,224 | $0 | Implemented |
DL0203 # 06 Y:2022 | 06 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $1,119 | $145 | Not Implemented |
DL0203 # 07 Y:2022 | 07 | 2022 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $567 | $0 | Implemented |
DL0203 # 08 Y:2022 | 08 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $88 | $117 | Implemented |
DL0203 # 09 Y:2022 | 09 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $508 | $1,000 | Implemented |
DL0203 # 10 Y:2022 | 10 | 2022 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,239 | $3,000 | Not Implemented |
DL0203 # 11 Y:2022 | 11 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,145 | $39 | Not Implemented |