Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,581
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0149 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,900 | $1,250 | Not Implemented |
DL0149 # 05 Y:2015 | 05 | 2015 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,140 | $40 | Implemented |
DL0149 # 06 Y:2015 | 06 | 2015 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $870 | $50 | Implemented |
DL0149 # 07 Y:2015 | 07 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,930 | $7,440 | Implemented |
DL0149 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $470 | $1,430 | Implemented |
DL0149 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $3,200 | Implemented |
DL0149 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $1,200 | Implemented |
DL0149 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,290 | $29,215 | Not Implemented |
MI0283 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $75,489 | $140,000 | Not Implemented |
MI0283 # 02 Y:2015 | 02 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $54,079 | $166,590 | Not Implemented |
MI0283 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $20,030 | $160 | Implemented |
MI0283 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,361 | $1,660 | Implemented |
MI0283 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,483 | $9,820 | Implemented |
MI0283 # 06 Y:2015 | 06 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,494 | $1,400 | Not Implemented |
MI0283 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $942 | $40 | Not Implemented |
MI0283 # 08 Y:2015 | 08 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $688 | $639 | Implemented |
MI0283 # 09 Y:2015 | 09 | 2015 | INSTALL OCCUPANCY SENSORS | $684 | $177 | Not Implemented |
SD0514 # 01 Y:2015 | 01 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $188,380 | $121,434 | Implemented |
SD0514 # 02 Y:2015 | 02 | 2015 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $34,024 | $1,200 | Implemented |
SD0514 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,935 | $2,000 | Implemented |
SD0514 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $2,376 | $3,380 | Implemented |
SD0514 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,336 | $400 | Not Implemented |
OK0904 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $4,880 | $14,220 | Implemented |
OK0904 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,563 | $180 | Implemented |
OK0904 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,580 | $12,793 | Not Implemented |