Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0057 # 18 Y:2010 | 18 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,000 | $0 | Implemented |
MZ0057 # 04 Y:2010 | 04 | 2010 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,597 | $250 | Implemented |
MZ0057 # 03 Y:2010 | 03 | 2010 | KEEP EQUIPMENT CLEAN | $5,750 | $0 | Implemented |
MZ0057 # 02 Y:2010 | 02 | 2010 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $145,366 | $500,000 | Not Implemented |
MZ0057 # 01 Y:2010 | 01 | 2010 | SHADE WINDOWS FROM SUMMER SUN | $259,173 | $46,607 | Implemented |
MZ0057 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $1,212 | $2,410 | Implemented |
MZ0057 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,198 | $10,240 | Implemented |
MZ0057 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,315 | $9,660 | Implemented |
MZ0057 # 09 Y:2010 | 09 | 2010 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,104 | $100 | Implemented |
MZ0057 # 08 Y:2010 | 08 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $186 | $300 | Implemented |
MZ0057 # 16 Y:2010 | 16 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $52 | $50 | Implemented |
MZ0057 # 15 Y:2010 | 15 | 2010 | USE OPTIMUM THICKNESS INSULATION | $11,828 | $5,000 | Not Implemented |
MZ0057 # 17 Y:2010 | 17 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $652 | $0 | Not Implemented |
MZ0057 # 19 Y:2010 | 19 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,660 | $18,000 | Implemented |
MZ0057 # 10 Y:2010 | 10 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,259 | $0 | Implemented |
MZ0057 # 13 Y:2010 | 13 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,940 | $0 | Implemented |
MZ0057 # 14 Y:2010 | 14 | 2010 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,194 | $2,000 | Implemented |
MZ0057 # 11 Y:2010 | 11 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,919 | $1,300 | Implemented |
MZ0057 # 12 Y:2010 | 12 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,016 | $0 | Implemented |
MZ0057 # 20 Y:2010 | 20 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,800 | $48,840 | Not Implemented |
MZ0057 # 21 Y:2010 | 21 | 2010 | INSULATE BARE EQUIPMENT | $248 | $300 | Implemented |
IA0454 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $201 | $150 | Implemented |
IA0454 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $980 | $400 | Implemented |
IA0454 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,229 | $300 | Implemented |
IA0454 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,365 | $1,560 | Implemented |