Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
Search IAC Recommendations
Sponsored by:
EERE AMO
IAC logo
Search IAC Recommendations
Due to University and State restrictions, IAC assessment activities at your local center may be on hold.
Contact your local center for more details on operating status and available services.

Click here for details about Coronavirus (COVID-19) Recovery Support programs

181

matching recommendations
Reset
NAICS 334413 Semiconductor and Related Device Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0573 # 05 Y:2005 05 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $500 $780 Implemented
CO0573 # 06 Y:2005 06 2005 USE SOLAR HEAT TO HEAT WATER $28,910 $121,820 Not Implemented
CO0573 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $8,750 $4,790 Implemented
CO0573 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,930 $13,186 Implemented
CO0573 # 09 Y:2005 09 2005 USE OPTIMUM THICKNESS INSULATION $3,590 $5,150 Not Implemented
CO0573 # 10 Y:2005 10 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,530 $0 Implemented
CO0573 # 11 Y:2005 11 2005 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,340 $0 Implemented
CO0573 # 12 Y:2005 12 2005 USE SOLAR HEAT FOR HEAT $730 $1,400 Not Implemented
CO0573 # 13 Y:2005 13 2005 RECOVER WASTE HEAT FROM EQUIPMENT $530 $1,600 Not Implemented
CO0573 # 14 Y:2005 14 2005 USE SOLAR HEAT TO HEAT MAKE-UP AIR $340 $3,400 Not Implemented
CO0528 # 01 Y:2003 01 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $20,940 $4,360 Implemented
CO0528 # 02 Y:2003 02 2003 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $13,340 $14,640 Not Implemented
CO0528 # 03 Y:2003 03 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,850 $16,010 Not Implemented
CO0528 # 04 Y:2003 04 2003 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,000 $3,000 Not Implemented
CO0528 # 05 Y:2003 05 2003 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $5,720 $13,150 Not Implemented
CO0528 # 06 Y:2003 06 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,940 $10,310 Not Implemented
TA0059 # 01 Y:2003 01 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $9,950 $0 Not Implemented
TA0059 # 02 Y:2003 02 2003 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $5,536 $500 Not Implemented
TA0059 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,885 $7,671 Implemented
TA0059 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,890 $200 Implemented
TA0059 # 05 Y:2003 05 2003 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,100 $585 Not Implemented
TA0059 # 06 Y:2003 06 2003 REPAIR FAULTY LOUVERS AND DAMPERS $2,040 $625 Not Implemented
AS0347 # 01 Y:2003 01 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,462 $0 Implemented
AS0347 # 02 Y:2003 02 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,330 $8,920 Implemented
AS0347 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,837 $60 Implemented