Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsNAICS | 334416 | Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0695 # 12 Y:2004 | 12 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $729 | $0 | Implemented |
UD0695 # 06 Y:2004 | 06 | 2004 | ADVERTISE PRODUCT OR SERVICE | $7,000 | $-40,240 | Implemented |
UD0695 # 05 Y:2004 | 05 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,056 | $0 | Implemented |
UD0695 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM TEMPERATURE | $7,076 | $9 | Implemented |
UD0695 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $7,720 | $0 | Implemented |
UD0695 # 02 Y:2004 | 02 | 2004 | AUTOMATE FINISHING PROCESS | $14,454 | $20,000 | Not Implemented |
UD0695 # 01 Y:2004 | 01 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $42,439 | $0 | Not Implemented |
UD0695 # 16 Y:2004 | 16 | 2004 | DISCONNECT BALLASTS | $327 | $7 | Implemented |
UD0695 # 13 Y:2004 | 13 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $397 | $756 | Implemented |
UD0695 # 15 Y:2004 | 15 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $339 | $0 | Implemented |
UD0695 # 17 Y:2004 | 17 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $237 | $213 | Implemented |
UD0695 # 14 Y:2004 | 14 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $420 | $340 | Not Implemented |
UD0695 # 07 Y:2004 | 07 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,434 | $0 | Not Implemented |
UD0695 # 11 Y:2004 | 11 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $784 | $0 | Implemented |
UD0695 # 08 Y:2004 | 08 | 2004 | USE MINIMUM SAFE OVEN VENTILATION | $2,564 | $0 | Implemented |
UD0695 # 10 Y:2004 | 10 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,110 | $0 | Implemented |
UD0695 # 09 Y:2004 | 09 | 2004 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,331 | $175 | Implemented |
UD0681 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,840 | $700 | Not Implemented |
UD0681 # 06 Y:2003 | 06 | 2003 | REDUCE VENTILATION AIR | $2,785 | $1,360 | Not Implemented |
UD0681 # 07 Y:2003 | 07 | 2003 | AIR CONDITION ONLY SPACE NECESSARY | $1,800 | $0 | Implemented |
UD0681 # 08 Y:2003 | 08 | 2003 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,740 | $0 | Implemented |
UD0681 # 09 Y:2003 | 09 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,095 | $1,268 | Not Implemented |
UD0681 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,862 | $7,947 | Implemented |
UD0681 # 14 Y:2003 | 14 | 2003 | INSTALL OCCUPANCY SENSORS | $105 | $160 | Not Implemented |
UD0681 # 01 Y:2003 | 01 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $82,000 | $1,490 | Implemented |