Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsNAICS | 334417 | Electronic Connector Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0361 # 08 Y:2019 | 08 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,145 | $1,980 | Implemented |
MI0361 # 07 Y:2019 | 07 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,880 | $1,446 | Not Implemented |
MI0361 # 06 Y:2019 | 06 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,612 | $160 | Implemented |
MI0361 # 05 Y:2019 | 05 | 2019 | AIR CONDITION ONLY SPACE NECESSARY | $5,773 | $9,476 | Not Implemented |
MI0361 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,278 | $17,214 | Implemented |
MI0361 # 03 Y:2019 | 03 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $17,548 | $3,600 | Implemented |
MI0361 # 02 Y:2019 | 02 | 2019 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $18,921 | $27,048 | Not Implemented |
MI0361 # 01 Y:2019 | 01 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,647 | $100,030 | Implemented |
TT0225 # 05 Y:2019 | 05 | 2019 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,118 | $1,900 | Not Implemented |
TT0225 # 04 Y:2019 | 04 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,140 | $3,390 | Not Implemented |
TT0225 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,576 | $3,500 | Not Implemented |
TT0225 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,037 | $53,169 | Not Implemented |
TT0225 # 01 Y:2019 | 01 | 2019 | APPLY FOR INVESTMENT INCENTIVES | $61,196 | $11,500 | Implemented |
LE0475 # 08 Y:2019 | 08 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,356 | $15,000 | Not Implemented |
LE0475 # 07 Y:2019 | 07 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,604 | $56,575 | Not Implemented |
LE0475 # 06 Y:2019 | 06 | 2019 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,265 | $46,000 | Not Implemented |
LE0475 # 05 Y:2019 | 05 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $50 | $200 | Implemented |
LE0475 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,513 | $12,830 | Implemented |
LE0475 # 03 Y:2019 | 03 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,128 | $10,000 | Not Implemented |
LE0475 # 02 Y:2019 | 02 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,177 | $2,000 | Not Implemented |
LE0475 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,240 | $0 | Implemented |
AS0465 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66,350 | $43,576 | Not Implemented |
AS0465 # 06 Y:2019 | 06 | 2019 | RECOVER MECHANICAL ENERGY | $4,582 | $20,880 | Not Implemented |
AS0465 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,608 | $3,900 | Not Implemented |
AS0465 # 04 Y:2019 | 04 | 2019 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,850 | $17,634 | Implemented |