Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
944
matching recommendationsNAICS | 33451 | Navigational, Measuring, Electromedical, and Control Instruments Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0614 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,010 | $12,000 | Implemented |
CO0614 # 04 Y:2008 | 04 | 2008 | USE SOLAR HEAT TO HEAT WATER | $3,910 | $84,000 | Not Implemented |
CO0613 # 01 Y:2008 | 01 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $27,040 | $12,030 | Not Implemented |
CO0613 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,230 | $3,000 | Not Implemented |
CO0613 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,500 | $3,000 | Implemented |
CO0613 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,060 | $120 | Not Implemented |
CO0613 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,330 | $9,130 | Implemented |
CO0613 # 06 Y:2008 | 06 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,300 | $39,600 | Not Implemented |
CO0613 # 07 Y:2008 | 07 | 2008 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,390 | $1,000 | Implemented |
SD0407 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,517 | $5,878 | Implemented |
SD0407 # 02 Y:2008 | 02 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $4,807 | $0 | Not Implemented |
SD0407 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,196 | $13,699 | Implemented |
SD0407 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,008 | $7,140 | Implemented |
SD0407 # 05 Y:2008 | 05 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,341 | $1,374 | Implemented |
SD0407 # 06 Y:2008 | 06 | 2008 | INSTALL SKYLIGHTS | $990 | $2,940 | Not Implemented |
IC0138 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,199 | $66,929 | Implemented |
IC0138 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $422 | $537 | Implemented |
IC0138 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $927 | $3,982 | Implemented |
IC0138 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,232 | $143,228 | Implemented |
IC0138 # 05 Y:2008 | 05 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,556 | $20,784 | Implemented |
IC0138 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,154 | $0 | Implemented |
IC0138 # 07 Y:2008 | 07 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,513 | $0 | Implemented |
IC0138 # 08 Y:2008 | 08 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $158 | $0 | Implemented |
IC0138 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $14,928 | $1,500 | Implemented |
MI0163 # 01 Y:2008 | 01 | 2008 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $600,000 | $200,000 | Implemented |