Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

944

matching recommendations
Reset
NAICS 33451 Navigational, Measuring, Electromedical, and Control Instruments Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0334 # 02 Y:2006 02 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $2,870 $1,000 Implemented
NC0334 # 03 Y:2006 03 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $8,466 $500 Implemented
NC0334 # 04 Y:2006 04 2006 RECOVER AND REUSE COOLING WATER $1,680 $620 Implemented
NC0334 # 05 Y:2006 05 2006 REDUCE VENTILATION AIR $10,892 $4,000 Implemented
NC0334 # 06 Y:2006 06 2006 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $3,773 $1,300 Implemented
NC0334 # 07 Y:2006 07 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $6,065 $0 Implemented
NC0334 # 08 Y:2006 08 2006 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,306 $8,000 Implemented
NC0334 # 09 Y:2006 09 2006 INSULATE BARE EQUIPMENT $5,061 $3,300 Implemented
NC0334 # 10 Y:2006 10 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,095 $100 Implemented
NC0334 # 11 Y:2006 11 2006 RECOVER WASTE HEAT FROM EQUIPMENT $9,138 $9,824 Not Implemented
NC0334 # 12 Y:2006 12 2006 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $5,012 $4,200 Not Implemented
AM0503 # 01 Y:2006 01 2006 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $16,230 $33,000 Not Implemented
AM0503 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,600 $500 Implemented
AM0503 # 03 Y:2006 03 2006 OPTIMIZE PLANT POWER FACTOR $6,550 $17,100 Not Implemented
AM0503 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,320 $300 Implemented
AM0503 # 05 Y:2006 05 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $930 $27 Implemented
AM0503 # 06 Y:2006 06 2006 REUSE RAGS UNTIL COMPLETELY SOILED $880 $0 Not Implemented
AM0503 # 07 Y:2006 07 2006 USE SYNTHETIC LUBRICANT $256 $0 Not Implemented
WI0503 # 07 Y:2005 07 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,742 $4,900 Not Implemented
WI0503 # 06 Y:2005 06 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,350 $640 Not Implemented
WI0503 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,506 $0 Not Implemented
WI0503 # 04 Y:2005 04 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,112 $1,000 Not Implemented
WI0503 # 03 Y:2005 03 2005 USE OPTIMUM THICKNESS INSULATION $8,005 $7,500 Not Implemented
WI0503 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,209 $21,960 Not Implemented
WI0503 # 01 Y:2005 01 2005 $47,772 $9,625 Not Implemented