Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsNAICS | 335 | Electrical Equipment, Appliance, and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0879 # 02 Y:2014 | 02 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,423 | $7,826 | Implemented |
OK0879 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,268 | $1,245 | Implemented |
OK0865 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,091 | $35,380 | Not Implemented |
OK0865 # 01 Y:2013 | 01 | 2013 | INSTALL SET-BACK TIMERS | $2,575 | $1,530 | Implemented |
OK0865 # 02 Y:2013 | 02 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $47,613 | $33,780 | Implemented |
OK0865 # 03 Y:2013 | 03 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $5,494 | $1,776 | Implemented |
OK0865 # 04 Y:2013 | 04 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,200 | $9,900 | Not Implemented |
OK0865 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $138 | $1,771 | Not Implemented |
OK0865 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,472 | $1,050 | Implemented |
OK0865 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,177 | $462 | Implemented |
OK0865 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,362 | $1,220 | Not Implemented |
OK0865 # 10 Y:2013 | 10 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,044 | $3,080 | Not Implemented |
OK0865 # 11 Y:2013 | 11 | 2013 | OPTIMIZE PLANT POWER FACTOR | $4,129 | $11,222 | Not Implemented |
OK0676 # 01 Y:2004 | 01 | 2004 | INSTALL OCCUPANCY SENSORS | $369 | $874 | Not Implemented |
OK0676 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $25,650 | $1,690 | Not Implemented |
OK0676 # 05 Y:2004 | 05 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,578 | $242 | Not Implemented |
OK0676 # 04 Y:2004 | 04 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,712 | $600 | Not Implemented |
OK0676 # 03 Y:2004 | 03 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,300 | $0 | Not Implemented |
OK0676 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,179 | $9,625 | Not Implemented |